Class LC Electrically Held Lighting Contactor

(Convertible to Mechanically Held)

Catalog numbers LCE00C*

Page 6 of 6

Replacement Parts and Accessories

Kit Type

Description

Catalog No.

Coil

24V 60Hz / 20V 50Hz

75LCC024A

115-120V 60Hz / 110V 50Hz

75LCC120A

200-208V 60Hz

75LCC208A

230-240V 60Hz / 220V 50Hz

75LCC240A

277V 60Hz / 240V 50Hz

75LCC277A

347V 60Hz

75LCC347A

460-480V 60Hz / 440V 50Hz

75LCC480A

575-600V 60Hz / 550V 50Hz

75LCC600A

Power Pole

Single power pole

49LCPP1A

Double power pole

49LCPP2A

 
Auxiliary Contact

1 NO/NC

49LCAC1PA

2 NO/NC

49LCAC2PA

Control Module

2-wire, 24VAC

49LCCM1A

2-wire, 110-120VAC

49LCCM2A

2-wire, 200-277VAC

49LCCM3A

3-wire, 24VAC

49LCCM4A

3-wire, 110-120VAC

49LCCM5A

3-wire, 200-277VAC

49LCCM6A

Component

# of Wire

Wire Range AWG
(Solid or Stranded)

Wire Temp

Torque
(lb-in)

Power Poles

1 or 2

#14 - 8*

75

o

 C Cu

35

Coil

1 or 2

#18 - 14

60o / 75

o

 C CU

15

Auxiliary Contacts

1 or 2

#22 - 12

60o / 75

o

 C CU

7 - 12

* #8 AWG is stranded only.

For replacement parts information or an application guide, visit our  
website at usa.siemens.com/controls, or contact your local Siemens  
sales office.

Siemens Industry, Inc. 
5300 Triangle Parkway 
Norcross, GA 30092

1-800-241-4453
[email protected]

usa.siemens.com/controls

Subject to change without prior notice. 
A5E31166555A-001
All rights reserved.
Printed in USA
©2013 Siemens Industry, Inc.

The information provided in this brochure contains merely general descriptions or 
characteristics of performance which in case of actual use do not always apply as 
described or which may change as a result of further development of the products.  
An obligation to provide the respective characteristics shall only exist if expressly 
agreed in the terms of contract. 

All product designations may be trademarks or product names of Siemens AG or 
supplier companies whose use by third parties for their own purposes could violate  
the rights of the owners.

Summary of Contents for LCE00C Series

Page 1: ...iary contact blocks are available in either single pole 49LCAC1PA or double pole 49LCAC2PA versions Auxiliary contacts can be installed on either side of the base When installed on the RIGHT side the auxiliary contact functions as a N C contact When installed on the LEFT side the auxiliary contact functions as a N O contact 2P 2P 2P 2P 2P 2P 2 P 2 P 2 P 2 P 2 P 2 P Electrically Held Standard Mecha...

Page 2: ...t from the N C indicator side Pull clip position power pole module onto the base and release 1 2 1 2 N F 1 2 N O N C Power Pole Installation Removing the Power Pole Modules Remove power pole module by inserting screwdriver into the plastic clip and pull it out to release the power pole module from the base 1 1 Auxiliary Contact Block Installation Insert one end of auxiliary contact module Snap opp...

Page 3: ... cover Class LC Electrically Held Lighting Contactor Convertible to Mechanically Held Catalog numbers LCE00C Page 3 of 6 Step 2 Remove coil assembly Step 3 Replace with new coil Step 4 Reinstall coil assembly and cover Torque 7 12 lb in Siemens Industry Inc A5E31166555A 001 ...

Page 4: ...e contactor is in the unlatched state If in the latched state push both tabs forward and release The Contactor should return to the unlatched state Class LC Electrically Held Lighting Contactor Convertible to Mechanically Held Catalog numbers LCE00C Page 4 of 6 Step 3 Remove coil assembly Siemens Industry Inc A5E31166555A 001 Unlatched state Latched state Step 4 Replace with new coil Step 5 Replac...

Page 5: ... electric code as required 2 Additional over current protection for control circuit may be required 3 When coil and line voltages are same the control voltage may be derived from the line for supply 4 Ground lug kit number 49D11960001 meets CSA standard 22 2 no 14 1973 and is rated for 1 conductor 2 14 AWG AL CU wire Contacts in positions 1 through 4 can be used as either NO or NC Contacts in posi...

Page 6: ... 2 18 14 60o 75o C CU 15 Auxiliary Contacts 1 or 2 22 12 60o 75o C CU 7 12 8 AWG is stranded only For replacement parts information or an application guide visit our website at usa siemens com controls or contact your local Siemens sales office Siemens Industry Inc 5300 Triangle Parkway Norcross GA 30092 1 800 241 4453 info us siemens com usa siemens com controls Subject to change without prior no...

Reviews: