02.2019
12/18
H47.ELEKS005EN-00
Electromechanical systems
Operating instructions
A-opener 2.1
4.2
Set the volume of the buzzer
The buzzer delivers the acoustic feedback of the opening process or malfunction.
The volume for the feedback of the opening process is adjustable in five stages from 0 % to 100 %. Coupled to this
is the sound volume of the button of the menu LED with exception of the stage 0%. The volume remains at 25%
here.
The volume for the feedback of malfunction is preset.
1
Volume of the
buzzer
System services
A
K
100 %
Couple device
A
B
K
B
75 %
Disconnect device
A
C
K
C
(50 %)
Log output
A
D
K
D
25 %
A
E
0 %
A
F
(Default settings)
K
H
Retrieve menu: Press button 8 sec
Long press: Press button 3 sec
Short press: Press button 1 sec
A
Magenta
C
Black
E
Red
K
Turquoise
L
Blue
B
White
D
Orange
F
Mint
H
Violet
2
[1] Level 1 [2] Level 1 main menu
[3] Level 2 adjustment range
[4] Legend
A
Main menu
Press button 1 x 8 sec
Save
selection
Press button 1 x
3 sec
A
Retrieve adjustment of the volume of the buzzer
Press button 1 x 3 sec
A
B
100 %
Press button 1 x 1 sec
A
C
75 %
Press button 2 x 1 sec
A
D
50 %*
Press button 3 x 1 sec
A
E
25 %
Press button 4 x 1 sec
A
F
Off
Press button 5 x 1 sec
*Default value on delivery
In case of a continual opening impulse at terminal 4, the tone output of the buzzer will be switched off after 7 sec at the latest.