![Siemens IONPURE VNX50HH-2 Operation & Maintenance Manual Download Page 39](http://html.mh-extra.com/html/siemens/ionpure-vnx50hh-2/ionpure-vnx50hh-2_operation-and-maintenance-manual_377179039.webp)
IONPURE
®
VNX50HH-2 CEDI Modules
Page 39
IP-MAN-VNX50HH2
APPENDIX A: VNX50HH-2 MODULE SPECIFICATIONS
A.1 Module
Dimensions and Weight
PART NUMBER
DIMENSIONS, WEIGHT
IP-VNX50HH-2
Height:
20 in (50.8 cm)
Width:
20 in (50.8 cm)
Length:
84.6 in (214.9 cm)
Weight (wet):
825 lb (375 kg)
A.2 VNX50-HH Module Inlet & Outlet Connections
Piping Connections
Size of installed PVC ports
on module
Alternate Polypropylene
Kit
Dilute Inlet
1 ½ ” Sch-80 female socket
50mm Butt Weld
Product Outlet
1 ½ ” Sch-80 female socket
50mm Butt Weld
Concentrate Inlet
1 ½ ” Sch-80 female socket
50mm Butt Weld
Reject Outlet
1 ½ ” Sch-80 female socket
50mm Butt Weld
See Drawings in Appendix B for location of connections. See Drawings in Appendix C for
Connection Drawings.
A.3 VNX50-HH Module Flow Rates, Pressure Drops & Plumbing Connections
Module VNX50-HH
80% Recovery Flow Rates
:
gpm (m
3
/hr)
80% Recovery minimum:
20 (4.5)
80% Recovery nominal:
40 (9.1)
80% Recovery maximum:
62.5 (11.4)
Pressure Drop psid (bar)
Typical @ nominal flow
20-30 (1.4-2.1)
Feedwater Conductivity (FCE)
<40 µS/cm
Product Resistivity (RO Permeate)
> 16 megohm-cm
Temp range
5-45 °C
Recovery
80-90%
Silica Removal
>90%
Sodium Removal
≥
99.5%
Chloride Removal
≥
99.8%
Feed / Product Plumbing
orientation
Inlet and outlet can be on
same end or opposite ends
Concentrate inlet / Reject Plumbing
orientation
Inlet and outlet can be on
same end or opposite ends
*
Actual performance can be evaluated using IP-Pro projection software available from Ionpure.