IONPURE
®
VNX50HH-2 CEDI Modules
Page 30
IP-MAN-VNX50HH2
3. Dissolve the sodium chloride (NaCl) in the water.
4. Start the cleaning pump and flush to drain for about three minutes.
5. Turn off the cleaning pump.
6. Drain the tank.
STEP
5:
Water
Flush to Drain
This step flushes the cleaning solution out of the system, and prepares the system for
return to operation.
1. Close the cleaning pump discharge valve. Keep product and reject lines directed to
drain and disconnect the cleaning equipment from the module.
2. Turn on the feed water supply to the system. Slowly open the feed valve to allow RO
product water to flow through the module to drain.
3. After flushing all residual cleaning solutions from the system, follow the initial start-up
procedures in Section 5 of this manual. Start without the DC power applied to the
VNX module for five minutes, then slowly ramp up to apply the normal DC power.