![Siemens IONPURE VNX50HH-2 Operation & Maintenance Manual Download Page 33](http://html.mh-extra.com/html/siemens/ionpure-vnx50hh-2/ionpure-vnx50hh-2_operation-and-maintenance-manual_377179033.webp)
IONPURE
®
VNX50HH-2 CEDI Modules
Page 33
IP-MAN-VNX50HH2
Are any
DC wires
loose?
Tighten connections
Feed
water temp
drop?
Excess
hardness in
CEDI reject?
Increase in DC voltage
is normal
Acid clean,
reduce CEDI feed
hardness and/or
lower CEDI recovery
Yes
No
No
Yes
Yes
No
Call you local service
provider
Troubleshooting Flow Chart - Increase in DC Volts
Page 1 of 1
START HERE
Caustic clean,
reduce CEDI feed
silica and/or
lower CEDI recovery
Excess
silica in
CEDI reject?
Yes
No
Cleaning removed
organics from resin:
review process design
and operation
Does NaCl/NaOH
cleaning help?
Yes
No