Summary of the system main functions
20
Building Technologies
Fire Safety & Security Products
08.2007
6
Summary of the system main functions
The main functions of the system are listed in the table below.
Function Keys
Description
Notes
Full or Partition Arm
<CODE> &
◄┘
Initiates full arm
Full Arm
<ARM>
Initiates full arm
Only if enabled by installer
Disarm during exit
<ARM>
Disarms the system during the
exit delay
Only when slow beeping is emitted
Disarm <CODE>
&
◄┘
Disarms the system
Stopping alarms
Arm Partition
<A> or <B>
Arms partition A or B
Press A or B for
2 seconds to arm the partition in account –
only if enabled by installer
Arm Stay
<STAY> & <CODE>
◄┘
Initiates partial alarm when the
user is at home
Only if enabled by installer
Arm Stay
>STAY>
Initiates partial alarm when the
user is at home
Disarm Stay
<CODE> &
◄┘
Disarms the system
Disarm Stay
<STAY>
Disarms the system
Bypass
<BYPASS> & Zone#
◄┘
Bypasses the zone #
Repeats the procedure to un-bypass
zones
Initiate Panic
<
♫
> & <CTRL>
Activates emergency alert
Press simultaneously during 2 seconds
Initiate Medical
Alarm
<
♫
> & <B>
Activates emergency alert
Press simultaneously during 2 seconds
Initiate Fire Alarm
<A> & <B>
Activates emergency alert
Press simultaneously during 2 seconds
Memory
<UP> Arrow
Initiates display of events from
memory.
◄┘
Cancels memory readout
Displays events and automatically scrolls
to the next event after 2.5 sec. (Use arrow
key to scroll manually)
Chime Enable/disable
<
♫
>
Enable or disable chime function
Holds the key for 2 sec to alternate. Only if
enabled by installer
Control
<CTRL> & Device#
◄┘
Activates or deactivates outputs
and devices
Press <CTRL> for 2 seconds
Change or Add
Users code
<PROG> & <Master
CODE>
◄┘
Activates program mode to add
or change user codes
Customize keypad
<CTRL> & <LEFT> arrow
Enters Local Edit Program mode
Press <CONTROL> and then <ARM> and
hold both simultaneously for 2 sec
Increase LCD backlight
level
<CTRL>&<STAY<
Hold <>CTRL and press <STAY>
repeatedly to increase light
Decrease LCD backlight
level
<CTRL>&>BYPASS>
Hold <CTRL> and press <BY-
PASS> repeatedly to decrease
light
Increase Keypad button
backlight level
<CTRL> & <UP>
arrow
Hold <CTRL> and press <UP>
arrow repeatedly to increase light
Decrease Keypad button
backlight level
<CTRL> & <DOWN>
arrow
Hold <CTRL> and press
<DOWN> arrow repeatedly to
decrease light
Increase buzzer tone
<CTRL> & <A>
Hold <CTRL> and press <A>
repeatedly to increase buzzer
tone
Decrease buzzer tone
<CTRL> & <B>
Hold <CTRL> and press <B>
repeatedly to increase buzzer
tone
Tab. 6
Summary of functions
When an operation has started incorrectly, press <ENTER>
◄┘
to exit and return to the previous
mode.
Pressing the <PROG> key for 2 sec returns back to the basic position.
Summary of Contents for IC60
Page 1: ...Building Technologies Fire Safety Security Products IC60 Security System User Manual ...
Page 4: ...4 Building Technologies Fire Safety Security Products 08 2007 ...
Page 22: ......
Page 23: ...Building Technologies Fire Safety Security Products IC60 Einbruchmeldesystem Benutzerhandbuch ...
Page 26: ...4 Building Technologies Fire Safety Security Products 08 2007 ...
Page 44: ......
Page 48: ...4 Building Technologies Fire Safety Security Products 08 2007 ...
Page 66: ......
Page 70: ...4 Building Technologies Fire Safety Security Products 08 2007 ...
Page 88: ......
Page 89: ...Building Technologies Fire Safety Security Products IC60 Sistema di sicurezza Manuale Utente ...
Page 92: ...4 Building Technologies Fire Safety Security Products 08 2007 ...
Page 110: ......
Page 114: ...4 Building Technologies Fire Safety Security Products 08 2007 ...