Virtual Network configuration
A31003-W1040-U101-1-7619, July 2006 DRAFT
136
HiPath Wireless Controller, Access Points and Convergence Software V4.0, C10/C100/C1000 User Guide
hwc_vnsconfiguration.fm
Authentication for a VNS
7.3.1
Vendor Specific Attributes
In addition to the standard RADIUS message, you can include Vendor Specific Attributes
(VSAs). The Controller, Access Points and Convergence Software authentication mechanism
provides six VSAs for RADIUS and other authentication mechanisms.
The first five of these VSAs provide information on the identify of the specific Wireless AP that
is handling the wireless device, enabling the provision of location-based services.
The RADIUS message also includes RADIUS attributes Called-Station-Id and Calling-Station-
Id in order to include the MAC address of the wireless device.
Attribute Name
ID
Type
Messages
Description
Siemens-URL-
Redirection
1
string
Returned from
RADIUS server
A URL that can be returned to redirect a
session to a specific Web page.
Siemens-AP-
Name
2
string
Sent to
RADIUS server
The name of the AP the client is associating
to. It can be used to assign policy based on
AP name or location.
Siemens-AP-
Serial
3
string
Sent to
RADIUS server
The AP serial number. It can be used
instead of (or in addition to) the AP name.
Siemens-VNS-
Name
4
string
Sent to
RADIUS server
The name of the Virtual Network the client
has been assigned to. It is used in assigning
policy and billing options, based on service
selection.
Siemens-SSID 5
string
Sent to
RADIUS server
The name of the SSID the client is
associating to. It is used in assigning policy
and billing options, based on service
selection.
Siemens-BSS-
MAC
6
string
Sent to
RADIUS server
The name of the BSS-ID the client is
associating to. It is used in assigning policy
and billing options, based on service
selection and location.
Table 6
Vendor Specific Attributes
>
Siemens-URL-Redirection is supported by MAC-based authentication.
Summary of Contents for HiPath C10
Page 299: ......