BA 5060 EN 04/2011
Table 10:
Grease quantities for the lower outputshaft bearing for shutdown period > 36 months
Type
Grease quantity (standard value in kg) for gear-unit size
105
106
107
108
109
110
111
112
H2NV
0.600
0.800
0.900
1.100
1.300
1.700
1.800
2.200
The lubricating points are identified with the following identification plate.
Fettschmierstelle
g Lithiumseifenfett
Betriebsstunden
nach
045DE
Lubricating point
g [ ] lithiumbased grease
after [ ] operating hours
7.2
Startup
Before startup, replace the yellow plastic screw plug with the wetair filter (see also
notice on the gear unit).
Prior to using the wetair filter, 2 of the 8 sealed bores at the underside of the wetair
filter must be opened.
7.2.1
Oil level
•
Check the oil level in the gearunit housing.
Depending on the features the following oil levels apply
1)
:
─ Middle of the oilsight glass.
─ Upper mark on the oil dipstick.
1)
Should both be available, use of the oil dipstick has priority.
When the oil is cool, the oil level should be at the upper mark on the oil dipstick
screwed in. When the oil is warm it may slightly exceed this mark. It must in no case
be allowed to fall below the mark. If necessary, top up to the correct level. The
greaselubricated output bearing is protected by an oildam pipe from oil
(see item 5.6.2). Excess oil may inundate the oildam pipe.
7.2.2
Connection of monitoring instruments
•
Prior to startup, the monitoring instruments (pressure monitor and other evaluating instruments) must
be connected and activated.
•
During startup, the signal of the pressure monitor should be bridged for approx. 20 seconds. This is
necessary since the pressure in the gear unit needs time to stabilize.
If the oil pressure is < 0.3 bar the gear unit must be stopped at once.
For operating and servicing the components described in section 6, the pertinent instructions
manuals and the specifications in section 5 must be observed.
For technical data, refer to the data sheet and/or the list of equipment.