9
GB
■
If warm water is not required for an extended period, set
the tank to frost protection mode with button 6
Only red LED 9 lights up.
■
The tank must be drained fully by our customer service
department or an authorised specialist in order to avoid
frost damage, if the appliance is disconnected from the
electrical supply.
■
The device should be disconnected from the mains supply
when working on the water supply.
Error signals
■
LEDs 9 and 2 flash
Overheating protection has been activated.
Call customer service.
■
LEDs 9 and 4 flash
The temperature sensor is defective.
Call customer service.
Cleaning
■
Clean externally with a mild cleaning agent. Do not use
aggressive or abrasive detergents!
Maintenance/Customer Service
■
Repairs and other maintenance work may only be
carried out by one of our authorized customer service
representatives in order to avoid potential sources of
danger.
■
When you contact customer service, please quote the E
and FD numbers on your appliance (Fig. A).
■
The first inspection must be carried out no later than 2
years subsequent to initial startup of the appliance. This
involves inspection of the protection anode which may
need to be replaced, and the appliance may need to be
cleaned and descaled. The customer service will suggest
the next inspection date for a service.
■
The power supply and the water supply must be shut off
before all work on the appliance.
T e c h n i c a l d a t a
Rated capacity
[l]
30
50
80
100
Rated voltage
[V]
220–240 (~ 50 Hz)
Rated output DGxxx37E
Rated output DGxxx37R
Rated output DGxxx37P
[W]
1500
2000
2000
Rated current DGxxx37E
Rated current DGxxx37R
Rated current DGxxx37P
[A]
6,5
8,7
8,7
Fuse protection
[A]
10
Protection type/class
IP24D
Rated over-pressure DGxxx37E
Rated over-pressure DGxxx37R
Rated over-pressure DGxxx37P
[Mpa]
0,9
0,9
0,6
Cold and warm water connection
G 1/2"
Corrosion prevention
Magnesium protection anode
Warm water temperature range
[°C]
approx. 35-75
Frost protection
[°C]
approx. 10
Insulation thickness
[mm]
30
35
Stand-by power consumption at
65 °C
[kWh/d]
0,65
0,85
1,05
1,25
Mixed water quantities at 40 °C
(15 °C/65 °C)
[l]
54
90
144
180
Heating time (inlet 12 °C -> 60 °C)
DGxxx37E
DGxxx37R/DGxxx37P
[min]
68
51
114
85
182
137
228
171
Weight [filled]
[kg]
49
70
107
131
Dimensions (H x D)
[cm]
58 x 39
65 x 45
90 x 45
109 x 45