Operating hardware
4.3 Web server
CP 1626
40
Operating Instructions, 11/2018, C79000-G8976-C434-03
Symbol
Color
Meaning
black
Component cannot be accessed/Status cannot be determined
•
"Status not available" is always displayed
when the CP 1626 is in STOP or during start up
evaluation by "Report system error" for all configured I/O modules and I/O systems after r
e-
starting the CP 1626.
•
However, this status can also be displayed temporarily during operation if a diagnostic inter-
rupt burst occurs on all communications processors.
•
It is not possible to determine the status of communications processors on a subsystem that
is connected to a communications processor.
green
Maintenance required
yellow
Maintenance demanded
red
Error - component failed or faulty
-
Error in a lower communications processor level
Navigation to other module levels
The status of individual communications processors/modules/submodules is displayed when
you navigate to other module levels:
●
To higher module levels via the links in the display of the module levels
●
To lower module levels via the links in the "Name" column