Siemens CCWC1345-LX Configuration Manual Download Page 2

Liefermöglichkeiten und technische Änderungen vorbehalten. 
Data and design subject to change without notice. / Supply subject to availability. 
© 2006 Copyright by 
Siemens Building Technologies AG 
 
Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger erkennt diese Rechte 
an und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder 
außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist. 
 
We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights 
and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our 
prior express written authorization, nor to use it for any purpose other than for which it was delivered to him. 
 

Dear Customer 

By selecting this SIEMENS product, you have chosen a professional device that 
guarantees the highest possible quality and reliability. We would like to thank you 
very much for your confidence in our products and kindly ask you to read the 
following instructions carefully before installing and using the product, in order to 
take full advantage of all quality features included in this product line. 

WARNING 

To reduce the risk of fire or electrical shock, do not expose this product to rain or 
moisture. It should be installed by a qualified service person and should conform to 
all local codes.  Please connect the equipment to a 12 V DC or 24 V AC Class 2 
power supply if the LP camera model is to be installed. 

Summary of Contents for CCWC1345-LX

Page 1: ...Fire Safety Security Products Siemens Building Technologies 1 3 CMOS Ultra Wide Dynamic Color Camera CCWC1345 LX CCWC1345 MX Configuration Manual ...

Page 2: ... thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him Dear Customer By selecting this SIEMENS product you have chosen a professional device that guarantees the highest possible quality and reliability We would like to thank you very much for your confidence...

Page 3: ...rol switch for twisted pair video out 14 5 2 2 RS485 termination 14 5 2 3 IRIS pin assignment 14 5 2 4 Y C terminal 14 5 2 5 External control terminal 15 5 3 OSD setting hierarchy 16 6 Install the camera 18 6 1 Installation 18 6 1 1 Using BNC composite video output 18 6 1 2 Using twisted pair video output 18 6 2 Function settings 19 6 2 1 PRESET 19 6 2 2 CAMERA SETUP 19 6 2 2 1 EXPOSURE 19 6 2 2 2...

Page 4: ...ON 26 6 2 5 7 MOTION LEVEL 26 6 2 5 8 MOTION AREA 26 6 2 5 9 SET ZONE POSI 26 6 2 5 10 SET ZONE SIZE 26 6 2 5 11 SET ZONE MOVE 27 6 2 5 12 MOTION TEXT 27 6 2 5 13 ALARM OUT 27 6 2 5 14 MOTION DELAY 27 6 2 6 REMOTE 28 6 2 6 1 ADDRESS 28 6 2 6 2 PROTOCOL 28 6 2 6 3 BAUD RATE 28 6 2 7 PRIVACY ZONE 28 6 2 8 BLC ZONE 29 6 2 9 SYNC MODE 30 6 2 10 BACK 30 6 2 11 EXIT 30 6 2 12 CANCEL 30 6 2 13 DEFAULT 30...

Page 5: ...gned to provide reasonable protection against harmful interference in a residential installation z This equipment may generate uses and can radiate radio frequency energy and if not installed and used according to instructions may cause harmful inter ference with radio communications z Be aware that any modifications not explicitly approved in this manual may void your equipment warranty z The shi...

Page 6: ... responsible agencies at Siemens Building Technologies Fire Security Products GmbH Co oHG D 76181 Karlsruhe European Directive 89 336 EEC Electromagnetic Compatibility Compliance with the European Directive 89 336 EEC has been proven by testing according to the following standards Emitted interference EN 61000 6 3 EN 55022 Class B Interference resis tance EN 50130 4 European Directive 73 23 EEC Lo...

Page 7: ... tripod bracket or table recommended by the manufacturer or sold with the video product Any mounting of the product should follow the manufacturer s instructions and should use a mounting accessory recommended by the manufacturer z Ventilation This video product should never be placed near or over a radiator or heat regis ter z Power sources This video product should be operated only from the type...

Page 8: ...er controls may result in damage and will often require extensive work by a qualified technician to restore the video product to its normal operation e If the video product has been dropped or the cabinet has been damaged f When the video product exhibits a distinct change in performance this indi cates a need for service z Replacement parts When replacement parts are required be sure the service ...

Page 9: ...pening the camera may expose you to dangerous voltages or other hazards Refer all servicing to qualified personnel only 2 2 Cleaning Do not touch the imaging surface of sensor Use a soft cloth moistened with alco hol to clean the surface if it is touched accidentally 2 3 Transportation Use the original packing material or materials of equal quality 2 4 CMOS characteristics The following conditions...

Page 10: ...n 500 TV lines horizontal Y C output Gamma correction 0 45 1 0 selectable Minimum illumination 0 5 lux F 1 4 AGC 30 dB 50 IRE video output Dynanic range 120 dB S N ratio 50 dB Slow shutter 2X 4X 8X 16X Gain control Selectable 0 6 12 18 24 up to 30 dB Backlight compensation 6 area selectable Center 1 Center 2 Up Half Low Half Middle Low Middle High Privacy zone 1 blocks Motion detect Motion alarm l...

Page 11: ...ol RS 485 Siemens B S U protocol MOLYNX D Twisted Pair Video Twisted Pair Video out Alarm IN 1CH Alarm OUT NC BW OUT selectable Tripod thread A 1 4 inch on bottom and top Power source CCWC1345 LX DC 12 V 10 regulated power supply AC 24 V 10 50 60 Hz CCWC1345 MX AC 100 240 V 10 50 60 Hz Power consumption CCWC1345 LX 4 VA max CCWC1345 MX 4 5 VA max Ambient conditions 10 55 C 95 max relative humidity...

Page 12: ... Wide Dynamic Color Camera 500 TVL PASL NTSC 90 260 V AC 2GF1183 8HB 0 55 Accessories not included in delivery PSU230 12 Power supply unit for 12 V DC cameras 2GF1800 8BE 0 12 CAPA2410 P Power supply unit for 24 V AC cameras 2GF1800 8BJ 0 30 4 1 Package contents z CMOS camera z Hexagonal wrench z 4 pins IRIS plug z CS C lens mount adaptor z EMI core LX 2 pcs MX 2 pcs z CD including remote control ...

Page 13: ...a part definition 1 Back focus adjust ring 2 Back focus lock screw 3 Tripod mount hole 4 IRIS connector 5 Power indicator 6 Video output 7 MX Power cord LX Power terminal 8 Control switch for Video Twisted Pair and RS485 9 External control terminal 10 Y C terminal 11 OSD control button 12 PC connection port for factory test only 13 Shield GND 14 DC12 V or AC 24 V 15 DC12 V or AC 24 V ...

Page 14: ...ncy dependent accentuation OFF ON Frequency dependent accentuation approx 6 dB with 5 MHz ON OFF Frequency dependent accentuation approx 6 dB with 5 MHz ON ON Frequency dependent accentuation approx 12 dB with 5 MHz Condition on delivery Output voltage 2 6 Vpp without accentuation 5 2 2 RS485 termination TERM RS485 terminal resistor OFF No terminal resistor ON With terminal resistor 100 Ohm 5 2 3 ...

Page 15: ...06 5 2 5 External control terminal Pin Pin Define Description 1 Data 2 Data RS 485 signal 3 Alarm IN 4 GND When Alarm IN GND be shorted the alarm function will be active please set ALARM FUNC to ON in OSD menu 5 Alarm out 6 COM Alarm out 7 Twist pair 8 Twist pair Twisted Pair Video output signal 9 GND GND ...

Page 16: ...Camera part and connector definition 16 Siemens Building Technologies Fire Safety Security Products 08 2006 5 3 OSD setting hierarchy ...

Page 17: ...Camera part and connector definition 17 Siemens Building Technologies Fire Safety Security Products 08 2006 ...

Page 18: ... adjust is necessary please unlock screw Enter Back Focus Format in OSD please refer to chapter 6 2 4 8 then rotate backfocus wheel till a sharp image appears Lock the screw tightly 6 1 1 Using BNC composite video output 1 Connect BNC cable to video output please refer to chapter 5 1 Camera part definition 2 Make sure that a proper BNC 75 Ohm cable is used 3 Switch on 75 Ohm termination in video r...

Page 19: ...eave modify mode 6 2 2 CAMERA SETUP Enter CAMERA SETUP submenu as shown in the figure Using UP DOWN key adjusts cursor to the item which wants to modify Press ENTER key to enter modify status Using UP DOWN key to select Mode After selected and then press ENTER key to leave modify Mode 6 2 2 1 EXPOSURE Setting ALC for Auto IRIS lens control or ELC for auto electronic shutter when using manual IRIS ...

Page 20: ...he R and B red blue values by press UP DOWN button Press LEFT RIGHT button to exit move cursor between R B and press ENTER button to exit 6 2 2 5 GAIN Adjust max GAIN 0 30 dB Move the cursor to the position as shown in figure Using UP DOWN button choose gain value from 0 dB to 30 dB Setting the lens level exposure level Move the cursor to the position as shown in the figure Push ENTER and use the ...

Page 21: ... figure Use UP DOWN button to choose from 0 to 10 6 2 3 D N SETUP Enter D N SETUP submenu as shown in the figure Using UP DOWN key to adjust cursor to the item which wants to modify Press ENTER key to enter modify status Using UP DOWN key to select Mode After selected and then press ENTER key to leave modify Mode CAMERA SETUP EXPOSURE ALC SHUTTER OFF LENS LEVEL 5 WB MODE AUTO GAIN 24 GAMMA 0 45 AP...

Page 22: ...n from COLOR into B W mode is 21 dB and back to COLOR mode point is 18 dB z B MID The switchover point of gain from COLOR into B W mode is 22 dB and back to COLOR mode point is 18 dB z C HIGH The switchover point of gain from COLOR into B W mode is 23 dB and back to COLOR mode point is 18 dB 6 2 3 3 D N DELAY Setting DELAY time for D N function Move the cursor to the position as shown in the figur...

Page 23: ...times as original The zoom value can be selected in 96 steps Move the cursor to the position as shown in the figure Press Enter and use UP DOWN button to choose the digital zoom value 6 2 4 4 DZOOM P T SET This function is only operational when digital zoom is selected Move the cursor to the position as shown in the figure Press Enter and use UP DOWN LEFT RIGHT to select visible area 6 2 4 5 CHROM...

Page 24: ...n to choose NTSC or PAL system 6 2 5 OTHER SETUP Enter OTHER SETUP submenu as shown in the figure Using UP DOWN Key to adjust cursor to the function which wants to modify Press ENTER key to enter Modify status and then using UP DOWN key to select Mode after selected and then press Enter key to leave modify status This function is present for test Move the cursor to the position as shown in the fig...

Page 25: ...y to leave modify status 6 2 5 3 ALARM TEXT Select the ALARM TEXT position press ENTER into modify mode as shown in the figure Using Left Right button choose position and use UP DOWN button choose text 0 9 A Z the max 24 characters 6 2 5 4 ALARM ACTION Use the UP DOWN button to select OFF OUT B W ALL OUT B W as shown in the figure 6 2 5 5 ALARM DELAY Use the UP DOWN button to select 0 5 10 15 20 s...

Page 26: ...otion detect sensitivity Use the UP DOWN keys to set the sensitivity in the range of 0 to 255 The value 0 corresponds to the highest sensitivity 6 2 5 8 MOTION AREA Enter MOTION AREA submenu as shown in the figure Using UP DOWN Key to adjust cursor to the function which wants to modify Press ENTER key to enter Modify status and then using UP DOWN key to select Mode after selected and then press En...

Page 27: ...T Use the UP DOWN button to select 0 5 10 15 20 sec For delay of ALARM operate timing as shown in the figure 6 2 5 14 MOTION DELAY Use the UP DOWN button to select 0 5 10 15 20 sec For delay of Motion ALARM operate timing as shown in the figure Alarm will be re set automatically after selected time MOTION OFF MOTION LEVEL LOW MOTION AREA MOTION TEXT ALARM OUT OFF MOTION DELAY 5 BACK MOTION OFF MOT...

Page 28: ... 6 2 PROTOCOL Protocol include Siemens U Siemens B Siemens S and MOLYNX D 6 2 6 3 BAUD RATE Baud Rate 2400 4800 9600 19200 6 2 7 PRIVACY ZONE Move the cursor to the position as shown in the figure Press ENTER to turn on the privacy zone mode than use UP DOWN and Left Right button to setting zone position when ok press ENTER and use UP DOWN and Left Right button to setting zone size and press ENTER...

Page 29: ...The BLC area will not display on screen A OFF The BLC function is off B CENTER 1 Backlight compensation window is like C CENTER 2 Backlight compensation window is like D UP Half Backlight compensation window is like E LOW half Backlight compensation window is like F Door Low Backlight compensation window is like G Door High Backlight compensation window is like MAIN MANU PRESET INROOM CAMERA SETUP...

Page 30: ...he camera is in the internal SYNC mode B LL The camera is in the line lock mode you can adjust the phase angle from 0 300 deg according The default is 300 deg 6 2 10 BACK Selection of next page and last page 6 2 11 EXIT Save all setting and exit 6 2 12 CANCEL Reset back to original settings 6 2 13 DEFAULT Recall factory settings MAIN MANU PRESET INROOM CAMERA SETUP D N SETUP OPTION OTHER SETUP REM...

Page 31: ...the government or the local authorities This crossed out wheeled bin symbol on the product means the product is covered by the European Directive 2002 96 EC The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health It is a precondition for reuse and recycling of used electrical and electronic equipment ...

Page 32: ...cs 9 COLOR BAR 24 D D N DELAY 22 D N LEVEL 22 D N MODE 22 D N SETUP 21 DEFAULT 30 Dimensions 10 DNR 24 DZOOM 23 E EXIT 30 EXPOSURE 19 F Function setting 19 G GAIN 20 GAMMA 21 General guidelines 7 L LENS LEVEL 20 M Mirror 23 MOTION 26 MOTION LEVEL 26 27 O Operation and storage 9 OPTION 22 Ordering data 12 OTHER SETUP 24 P Package contents 12 Pin definiton 14 PRESET 19 PRIVACY ZONE 28 Product specif...

Page 33: ...33 Siemens Building Technologies Fire Safety Security Products 08 2006 ...

Page 34: ...sruhe www sbt siemens com 2006 Copyright by Siemens Building Technologies AG Data and design subject to change without notice Supply subject to availability Printed in the Federal Republic of Germany on environment friendly chlorine free paper Document no A24205 A336 B315 Edition 08 2006 ...

Reviews: