Basic Hicom settings for connection to 150 E Office Point 1.0
Basic settings
Nur für den internen Gebrauch
A31003-E1320-S100-4-7620
4-16
Service Manual
–
Not used: for special extensions which cannot use Caracas Desk but which
are connected, e.g. entrance telephones, service extensions for which call
detail recording is not carried out via Caracas Desk, etc.
●
If conflicts arise between the extension numbers, the customer data is not trans-
ferred back to Hicom and a message regarding the conflict is output. Please note
that conflicts can also arise with codes 7..., 8..., 9... and 0 (for routes by default,
etc.). These codes can only be checked or changed with Assistant E.
●
Write the data to Caracas Desk (via the Transfer/Write to Desk menu)
The wake-up service is located at subscriber 21 (with the default extension number
51).
A name may not be set in Hicom for the configured extensions. Names are automat-
ically assigned at check-in.
Names must are also be assigned for service extensions and booths at check-in.
Names are only deleted for guests at check-out.