background image

6

G

1

2

A

180

1

2

3

S

L

1

Befestigungsplatte vom Gerät nehmen.

Schablone 

„S“

ausbrechen.

2

Schablone wie dargestellt an die
Befestigungsplatte anlegen und auf die
Mischbatterie stellen.

Befestigungsbohrungen markieren.

Hinweis:

Auf waagrechte Lage der
Befestigungsplatte achten!

Bereits vorhandene Bohrlöcher/Dübel
anderer Kochendwassergeräte können
wiederverwendet werden. Dazu die
passenden Löcher in der
Montageplatte auswählen.

3

War ein Siemens Kochendwassergerät

BK 0562

montiert, Lasche 

„L“

nach

außen biegen und vorhandene
Bohrlöcher/Dübel verwenden.

1

Detach the mounting plate from the
appliance.

Break off the template 

“S”

.

2

Hold the template against the mount-
ing plate, as shown, and place it over
the mixer tap.

Mark the position of the holes for
mounting the plate.

Note:

Make sure that the mounting plate is
absolutely horizontal!

Any holes in the wall and rawlplugs
that remain from a previous water
heater can be used again. Simply
identify the corresponding holes in the
mounting plate.

3

If the previous water heater was a
Siemens 

BK 0562

, bend strap 

“L”

outwards and use the existing holes
and rawlplugs.

1

Снимите с нагревателя крепежную
плиту.

Выломайте шаблон 

„S“

.

2

Наложите шаблон, согласно
рисунку, на крепежную плиту и
установите его на смеситель.

Отметьте крепежные отверстия на
стене.

Указание:

Следите за тем, чтобы крепежная
плита находилась в горизонтальном
положении!

Если прежде на этом месте был
смонтирован другой нагреватель, то
Вы можете использовать подходя-
щие для крепежной плиты отвер-
стия в стене. 

3

Если был смонтирован нагреватель
типа 

BK 0562

, то тогда необходимо

выгнуть наружу накладку 

„L“

и

использовать имеющийся крепеж и
отверстие.

1.

Wasseranschluss

1.

Water connection

1.

Подключение воды

2.

Bohrlöcher anzeichnen

2.

Marking the holes to be
drilled

2.

Отметка крепежных
отверстий

Summary of Contents for BK 1010D

Page 1: ... to flow freely out of the outlet and overflow pipes Do not attach an aerator to the outlet pipe Do not place any objects on the appliance Ensure that the mains cable does not come into contact with any of the hot parts of the appliance The water heater will become very hot during use Keep children away from the heater The water tank mixer tap with outlet pipe and overflow pipe can all reach a tem...

Page 2: ...Заполните бак водой 2 Регулятор температуры установите в одно из положений от теплой до кипящей 3 Включение нажмите на клавишу включения 4 Выключение При установке низкой температуры прибор отключится самостоятельно При установке более высокой температуры прибор необходимо отключать вручную для этого регулятор температуры поворачива ется против часовой стрелки до упора 5 Горячую воду можно использ...

Page 3: ...corrosive Wash off any spillage with water immediately Observe the instructions for use provided by the manufacturer The device must be descaled if the following situations apply after selecting the maximum temperature setting the water does not come to the boil heater and pilot lamp switch off and on at intervals without the buzzer sounding the flow of hot water out of the outlet pipe is signific...

Page 4: ...s the heater plugged in Is the fuse in the domestic wiring in order Has the heater cooled down sufficiently since the last time it was used to boil water By eliminating these possible reasons for the fault you will avoid calling out a service engineer unnecessarily When you call Customer Service be prepared to quote the E and FD numbers for your appliance You will find these numbers on the undersi...

Page 5: ...ating instructions Leave a gap of at least 30 cm above the top edge of the appliance housing See Dimensions on Page 10 The water heater must be mounted so that it is absolutely perpendicular Use a standard pipe joining piece to compensate for an uneven wall surface See Page 10 For an additional water connection use a standard 50 mm branch adapter See Page 10 Check the length of the mains connectin...

Page 6: ...ng plate is absolutely horizontal Any holes in the wall and rawlplugs that remain from a previous water heater can be used again Simply identify the corresponding holes in the mounting plate 3 If the previous water heater was a Siemens BK 0562 bend strap L outwards and use the existing holes and rawlplugs 1 Снимите с нагревателя крепежную плиту Выломайте шаблон S 2 Наложите шаблон согласно рисунку...

Page 7: ...ition of socket Hook the heater onto the mounting plate Attach and tighten the water intake and outlet pipes Insert the overflow pipe Сетевой шнур А вложите в паз влево или вправо в зависимости от расположения розетки Нагреватель навесьте на крепежную плиту Плотно прикрутите соединительную и сливную трубы Вставьте сточную трубу 3 Montageplatte befestigen 3 Fixing the mounting plate 3 Крепление мон...

Page 8: ...cket unit If necessary fit a longer mains connecting cable See Page 9 Do not plug the heater in to the electricity supply until it has been mounted on the wall The maximum water flow rate is 10 l min i e 1 litre of water takes 6 seconds to flow into the tank Кран G полностью откройте Поворотом дроссельного винта D на нижней части смесителя макс пол оборота установите необходимый расход воды Нагрев...

Page 9: ...etzstecker ziehen Anschlussleitung wechseln Unplug the heater from the electricity supply before changing the cable Changing the mains cable Перед заменой сетевого кабеля выта щите сетевую вилку из розетки Замена сетевого кабеля Achtung Warning Осторожно ...

Page 10: ... 2 Wall mounting using commercially available adapter piece a 30 mm long 3 Wall mounting using commercially available adapter piece b 50 mm long equipped with an additional water connection If the heater is not going to be mounted flush on the wall use a standard pipe connecting piece and bend stand off A to the appropriate position Distance from wall Dimensions 1 Нагреватель монтируется непосредс...

Page 11: ...thermostat X1 Power input terminals Circuit diagram E1 Нагревательный элемент H1 Сигнальная лампа N1 Ограничитель температуры N2 Регулятор температуры с защитой от перегрева X1 Клемма подключения к сети Принципиальная схема E1 Heizung H1 Signallampe N1 Temperatur Wählbegrenzer N2 Schutz Temperaturregler X1 Netzanschluss ...

Page 12: ...Siemens Electrogeräte GmbH 86 692 074 Printed in Germany 02 03 DE GB RU ...

Reviews: