Example 1 – Fully equipped segment
25
Siemens AB
Security Products
03.2014
5
Example 1 – Fully equipped segment
The
database
in the Bewator Entro an SR35i to address a maximum of 32 wire-
less doors and 9 routers.
The
wireless functions
in an SR35i cannot however connect directly to more than
six RF9 routers or to more than 14 door units. If there are more than 14 door units
in the segment SR35i must be completed with at least one more RF9.
The example shows, to the right, how the three routers and the eighteen doors
must be configured
after
router 1-6.
Fig. 11 Example 1 – Maximum units for an SR35i