s
Operating manual PA
43
Disconnect the pyrometer from any voltage source
Activate or deactivate the termination of the respective partici-
pant (see termination of RS485 bus)
Install all required electric connections
Connect the converter with the PC
Install the converter according to instructions
Connect the voltage supply for the pyrometers
Adapt the addresses of the participants
Start CellaView
Select the correct COM port or use the CellaView search func-
tion.
11.4 Termination of RS485 bus
The terminal resistor of the pyrometer must be activated on the relevant
bus end. For this purpose set the DIP switches to ON. Deactivate the
termination with the remaining pyrometers.
12
Operation of the pyrometer via terminal program
By default, the pyrometer has fully integrated communications software
to the point-to-point connection with a PC. As an alternative to the Cel-
laView software, all parameters that are required for a measurement da-
ta acquisition or a general configuration of the pyrometer can be config-
ured via a simple terminal connection using the terminal program.
Most key parameters are directly available in the main menu. Further
functions are contained in submenus. Navigation within the menus is ex-
plained in the following graphics:
Summary of Contents for 7MC3040-...
Page 1: ...Digital Radiation Pyrometer PA 1x 2x 3x 7MC3040 Operating Manual 04 2017 ...
Page 2: ......
Page 8: ...s Operating manual PA ...
Page 93: ...s Operating manual PA 85 29 Dimensions ...
Page 97: ...s Operating manual PA 89 31 1 Mounting angle PA 11 K Pyrometer PA Mounting angle PA 11 K ...
Page 98: ...s Operating manual PA 90 31 2 Polarising filter Pyrometer PA Polarising filter PA 20 P ...
Page 101: ...s Operating manual PA 93 31 6 Cable VK 02 A Ident Nr 101 3909 ...
Page 102: ...s Operating manual PA 94 31 7 Cable VK 02 F Ident Nr 103 1446 ...
Page 103: ...s Operating manual PA 95 32 Mounting combinations 32 1 Mounting combination PA 20 007 ...
Page 104: ...s Operating manual PA 96 32 2 Mounting combination PA 20 010 ...
Page 111: ...s Operating manual PA 103 ...
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......