1
05.01
1.1 Overview of SIMODRIVE 611
1-26
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Matching, isolating
transformer
Types, graduated from
3–ph. 200 V AC to
3–ph. 575 V AC for
S
TN systems
S
TT systems
Line supply connection
See Chapter 7
Infeed modules
See Chapter 6
Power modules
See Chapter 5
Power module
Internal cooling
with internal fan
Power
module
External
cooling
Power module with
hose cooling
or
600 V DC
Monitoring module
TN system
3–ph. 360 V AC with Derating
3–ph. 400 V AC
3–ph. 415 V AC
3–ph. 480 V AC
3–ph. 400 V AC
Unregulated
infeed module
Infeed/regenerative
feedback module,
internal cooling
1)
HF commutating
reactors
Line filter
External
pulsed
resistor
2)
0.3/25 kW
Pulsed
resistor
module
External
pulsed resistor
1.5/25 kW
Capacitor
module
Refer to
Chapter
6.7.1
Line filter
HF commutating
reactor for 28 kW
UI module
S
Residual current devices
S
Installation altitude > 2000 m
1) Alternatively, external cooling and hose cooling possible.
Version as for the power modules.
2) Only for 28 kW UI module
Mounting frame
with mounted
fan
Damping
resistor
Fig. 1-2
Overview of the SIMODRIVE 611 drive system
1 Overview of the Drive System
10.04
02.12