4
05.01
4-82
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Table 4-1
Overview of the control units/boards
Closed–loop control module
Variant
Axes
Motor encoder
Motors
1)
Optional
interfaces
SIMODRIVE 611
with digital setpoint interface for
FD and MSD
High
Perfor-
mance
control
2
Incremental
encoders sin/cos
1 V
PP,
EnDat
SRM: 1FT6, 1FK, 1FE1,
1FW6, 2SP1
IM
1PH, 1PM
SLM: 1FN
Standard: 1LA
Third–party: If suitable
SIMODRIVE 611
with digital setpoint interface for
FD and MSD
High
Perfor-
mance
control
1
Incremental
encoders sin/cos
1 V
PP,
EnDat
SRM: 1FT6, 1FK, 1FE1,
1FW6, 2SP1
IM:
1PH7, 1PM
SLM: 1FN
Standard: 1LA
Third–party: If suitable
SIMODRIVE 611
with digital setpoint interface for
FD and MSD
High
Standard
control
2
Incremental
encoders sin/cos
1 V
PP,
EnDat
SRM: 1FT6, 1FK, 1FE1,
2SP1
IM:
1PH7, 1PM6
Standard: 1LA
Third–party: If suitable
SIMODRIVE 611
with digital setpoint interface for
hydraulic/analog
Linear drives HLA/ANA
2
Incremental
encoders sin/cos
1 V
PP
, EnDat,
SSI (SW 1.2.4
and higher)
Hydraulic linear axes/ana-
log axis
1) SRM:
Synchronous rotating motor
IM:
Induction rotating motor
IM:
Synchronous linear motor
Standard:
Standard motor
Third–party:Unlisted motor
4 Control Units
10.04