05.2003
Parameterizing Steps
Siemens AG
6SE7087-6JP60
SIMOVERT MASTERDRIVES
Operating Instructions
9-1
9 Parameterizing
Steps
For a detailed description of the parameters of the unit, please refer to
Section 6 "Parameterizing steps" of the Compendium.
Detailed parameterization should always be used in cases where the
exact application conditions of the units are not known beforehand and
detailed parameter adjustments need to be made locally, e.g. on initial
start-up.
1. Power section definition (P060 = 8)
2. Board definition
(P060 = 4, see Compendium, section 6.3.2)
3. Drive definition
(P060 = 5)
4. Function adjustment.
Motor
Motor
encoder
Supply
conditions
Optional
boards
Power sections
CUVP
Power section definition
(P060 = 8)
Drive setting
(P060 = 5)
Function adjustment
A
s
-d
e
liv
er
e
d
s
tat
e
Parameterizing with existing parameter files (download, P060 = 6)
Parameterizing with user settings (fixed setting, P060 = 2)
Factory settings (parameter reset) (P060 = 2)
Board configuration
(P060 = 4)
Pr
o
c
ed
ur
e
s
f
o
r
qui
c
k
pa
ram
e
te
ri
z
a
ti
o
n
De
ta
ile
d
par
a
m
e
ter
iz
a
ti
o
n
Parameterizing with parameter modules(quick parameterization, P060 = 3)
Fig. 9-1
Detailed and quick parameterization