Pin
Signal name
Type
Meaning
1
P5HW
V, O
Supply voltage 5 V, max. 100 mA
2
-
n.c.
3
HW1_A
I
Handwheel pulses track A
4
HW1_XA
I
Handwheel pulses track A (negated)
5
M
V
Ground
6
M
V
Ground
7
HW1_B
I
Handwheel pulses track B
8
HW1_XB
I
Handwheel pulses track B (negated)
9
-
n.c.
10
P5HW
V, O
Supply voltage 5 V, max. 100 mA
5.1.9
Status LEDs
Table 5-10
Meaning of the status LEDs
No.
Color
Meaning
H1
Green
Power OK
H2
Green
PROFINET LED (BUS SYNC)
H3
Red
PROFINET LED (BUS FAULT)
5.1.10
Switch S2
A logical address can be assigned to the MCP for communication via Ethernet using the 10-bit
switch S2.
Table 5-11
Basic setting of the switch S2
1-8
9
10 Meaning
See Table "Settings of switch S2"
on
on PN
off
off
IE (default)
MCP set up as PN
The two switches S2-9 and S2-10 must be set to "on" in order for PN functionality to be
supported.
Connecting
5.1 interfaces
ONE MCP Part 1: MCP xxxx
Equipment Manual, 07/2020, A5E50324729B AA
41