Technical data
6.2 Output
SITOP PSU6200 3ph
Equipment Manual, 02.2020, A5E44623402-1-76
37
6.2
Output
6EP3433-7SB00-0AX0
(24 V/5 A)
6EP3434-7SB00-3AX0
(24 V/10 A)
6EP3436-7SB00-3AX0
(24 V/20 A)
Output
Regulated, isolated DC voltage
Rated voltage U
out rated
DC 24 V
24 V
24 V
Total tolerance, static ±
± 3 %
± 3 %
± 3 %
Static line regulation,
approx. ±
0.05 %
0.1 %
0.1 %
Static load regulation,
approx. ±
0.6 %
0.2 %
0.2 %
Residual ripple
Peak-peak, max.
25 mV
Spikes peak-peak, max.
(bandwidth, 20 MHz)
25 mV
Adjustment range
24 - 28 V
Output voltage can be
adjusted
Yes
Output voltage setting
Using a potentiometer
Status display
LED green for 24 V O.K.
LED green for 24 V O.K.,
Diagnostics monitor, see Chapter Status displays and signal-
Signaling
Relay contact (NO contact, contact rating 24 V AC/0.1 A; 30 V DC/0.1 A) for 24 V O.K.
Response when switching
on/off
Overshoot of U
out
> 20 V
Overshoot of U
out
> 20 V or of U
out
> 23 V
Starting delay, max.
25 ms
130 ms
230 ms
Start delay, typ.
16 ms
80 ms
215 ms
Voltage rise
400 V / 500 V AC max.
80 ms
80 ms
80 ms
Voltage rise
400 V / 500 V AC typ.
70 ms
80 ms
80 ms
Rated current I
out rated
5 A
10 A
20 A
Current range
•
Remark
0 - 5 A
6 A to 45 °C
60 ... 70 °C derating:
3 % I
out rated
/K
0 - 10 A
12 A to 45 °C
60 ... 70 °C derating:
3 % I
out rated
/K
0 - 20 A
24 A to 45 °C
60 ... 70 °C derating:
3 % I
out rated
/K
Active power output, typ.
120 W
240 W
480 W
Overload capability (Extra
Power)
7.5 A for 5 s/min
15 A for 5 s/min
30 A for 5 s/min
Can be connected in par-
allel to increase the power
rating
No
Yes
Yes
Summary of Contents for 6EP3433-7SB00-0AX0
Page 8: ...Safety instructions SITOP PSU6200 3ph 8 Equipment Manual 02 2020 A5E44623402 1 76 ...
Page 22: ...Mounting removal SITOP PSU6200 3ph 22 Equipment Manual 02 2020 A5E44623402 1 76 ...
Page 54: ...Ambient conditions SITOP PSU6200 3ph 54 Equipment Manual 02 2020 A5E44623402 1 76 ...
Page 62: ...Environment SITOP PSU6200 3ph 62 Equipment Manual 02 2020 A5E44623402 1 76 ...