Connection panels on the system unit
Connecting the console to the system unit
•
Remove the cover at the rear of the system unit.
• You can now begin cabling work at the system unit connection panel:
Plug the appropriate end of the console connecting cable into the port for the
console on the system unit (into the first SR, SX or SY connector row).
Secure the connector.
Connecting additional terminal devices to the system unit
• Ensure that the power cords of the terminal devices are not connected to the power
supply when connecting cables between the system unit and the terminal devices.
• The device connecting cables must have a slack of approximately 50 cm in order to
avoid tension on the connectors.
Connection by means of standard SS97 or V.24/V.28 interfaces
•
Proceed as follows for all terminals and printers:
Plug the connecting cable into the terminal device as described in the operating
manual for the device.
Plug the free end of the connecting cable into the appropriate SS97 or V.24
socket on the system unit.
Note
97808 graphics terminals must be distributed evenly over the available I/O
processors since they place a considerably higher load on the system unit than
other terminal devices.
32
U6389-J-Z146-4-7400
Summary of Contents for MX300 Series
Page 1: ...SIEMENS NIXDORF Modelle mit Intel Prozessor MX300 Operating Manual Intel based models ...
Page 3: ...Betriebsanleitung MX300 Modelle mit Intel Prozessor Ausgabe Juli 1992 ...
Page 12: ......
Page 15: ...Grundausbau und Ausbaumöglichkeiten U6389 J Z146 4 7400 9 ...
Page 21: ...IMD Anschluß U6389 J Z146 4 7400 15 ...
Page 24: ......
Page 26: ...MX300 aufstellen Abbildung 4 Grundausstattung 20 U6389 J Z146 4 7400 ...
Page 37: ...Anschlußfelder der Systemeinheit U6389 J Z146 4 7400 31 ...
Page 56: ...Systemeinheit überprüfen Systemeinheit überprüfen 50 U6389 J Z146 4 7400 ...
Page 57: ...Systemeinheit überprüfen U6389 J Z146 4 7400 51 ...
Page 58: ......
Page 60: ......
Page 76: ......
Page 78: ...Zubehör Zubehör für den MX300 72 U6389 J Z146 4 7400 ...
Page 80: ......
Page 91: ...MX300 Operating Manual Intel based models Edition July 1992 ...
Page 103: ...Basic configuration U6389 J Z146 4 7400 9 ...
Page 112: ......
Page 114: ...Setting up your MX300 Fig 4 Basic configuration 20 U6389 J Z146 4 7400 ...
Page 132: ......
Page 138: ......
Page 141: ...Troubleshooting What to do if U6389 J Z146 4 7400 47 ...
Page 142: ...Troubleshooting 48 U6389 J Z146 4 7400 ...
Page 143: ...Troubleshooting U6389 J Z146 4 7400 49 ...
Page 144: ...Checking the system unit Check system unit 50 U6389 J Z146 4 7400 ...
Page 145: ...Checking the system unit U6389 J Z146 4 7400 51 ...
Page 146: ......
Page 148: ......
Page 157: ...3 1 2 floppies Fig 18 Inserting and removing a 3 1 2 floppy disk U6389 J Z146 4 7400 63 ...
Page 164: ......
Page 166: ...Accessories Accessories for your MX300 Item Order no Old order no 72 U6389 J Z146 4 7400 ...