EXC/RTX19 - USER & MAINTENANCE MANUAL - rev.1.5 - 05/16
Page 42
Field #34: I/O pin allocation and logic level setup
As described in the proper section, there are at least 4 I/O lines which may be associated to
corresponding pins of the parallel remote I/O connector on the rear panel. This submenu permits
to chose the corresponding function to associate to the pins with the following options:
Inputs:
PIN 6: AUDIO MUTING
REMOTE LOCK
Outputs:
PIN 2: MODULATION OK
REMOTE LOCKED
PIN 7: ALARM
FIELD GOOD
PIN 3,8: FIELD GOOD
ALARM
The factory default is the first line for each pin. All of these lines may be preset active high or
low in the same menu.
As for the Transmitter, when "Remote Locked", the apparatus cannot be changed in its presets
from front panel knob before exciting from this condition. The input pin #6 may be associated to
a function which force this status ("Remote Locked"). In this case every temptative to change the
setup will invoke menu field #21 to permit local control.