background image

Introduction

4

04.2016

KFV

1. 

Introduction

1.1 

Target group of this documentation

This documentation is intended for use by specialists only. All work described in this doc-
ument is to be performed by experienced professionals with training and practice in the 
assembly as well as commissioning and maintenance of multi-point locks. Safe and proper 
assembly of these locks hinges is not possible without expert knowledge.

1.2 

Intended use

1.2.1 

Installation location

•  The multi-point lock is suitable for installation in single-sash and double-sash doors in 

permanent buildings. 

•  The multi-point lock may only be installed in doors that have been fitted in a technically 

sound manner.

•  The door design must permit use of the multi-point lock.

1.2.2 

Locking part and hardware

•  The use of any additional devices to keep the door closed (with the exception of a door 

closer) is not permitted. If a door closer is installed, it must not impede operation of the 
door by children, the elderly or infirm.

•  Repair of the multi-point lock is not permissible. If the multi-point lock is damaged, it must 

be replaced by KFV or repaired by a service agent authorised by KFV.

•  Only KFV frame parts with Q adjustment may be used.

1.2.3 

Transport

•  Always transport the multi-point lock in a vertical position, whether uninstalled or installed 

in the door leaf.

•  Do not place the multi-point lock heavily on the ground when it is unpackaged, as this can 

damage the lock.

•  Do not carry the door by the lever handle or hardware when transporting it.
•  Opening/closing/locking: It must be possible to open and close the door easily. 

A protruding latch and /or deadbolt must not impede the opening of the door.

17

See note on page 17 for transport when installed in an element.

•  The locking elements must always engage freely in the lock striker of the frame parts. 

1.3 

Improper use

•  Do not use for escape doors.
•  The multi-point lock is not designed to accommodate changes to its shape or seal which 

arise as a result of differences in temperature or changes to the building.

•  The multi-point lock must not be used in doors for wet rooms or rooms in which the air 

contains aggressive or corrosive components.

•  Foreign objects and/or materials which impede or prevent proper use must not be placed 

within the opening range, the locking system or the striker plates.

•  The multi-point lock must not be interfered with and/or modified.
•  Locking elements must not be misused to hold the door open.
•  Movable or adjustable locking pieces (e.g. deadbolt, latch) must not be painted over.

Summary of Contents for KFV AS3500

Page 1: ...S C H E N G L I S H F R A N A I S E S PA O L I TA L I A N O N E D E R L A N D S E S K P O L S K I Assembly instructions AS3500 Multi point lock Window systems Door systems Comfort systems ASSEMBLY IN...

Page 2: ......

Page 3: ...ning the latch optional 11 2 4 Installing the A opener optional 12 2 5 Installing the door arrester or daytime release optional 13 2 6 Screwing on the multi point lock 15 2 7 Cutting the door frame 16...

Page 4: ...frame parts with Q adjustment may be used 1 2 3 Transport Always transport the multi point lock in a vertical position whether uninstalled or installed in the door leaf Do not place the multi point lo...

Page 5: ...ccording to our assembly instructions Use the clamp included in the delivery supplied for assembly Remove any splinters from the lock mortise after milling Once the lock is installed do not perform me...

Page 6: ...ns and symbols 6 See note on page 17 for transport when installed in an element This symbol indicates that you should read information given at the relevant point of the instructions The number in the...

Page 7: ...20 290 130 B003 2400 760 980 1020 270 130 B039 1700 760 355 952 263 62 B041 1700 760 605 952 13 62 B166 1855 760 730 952 43 62 B253 2170 760 980 952 108 62 B296 2170 760 355 1020 665 130 B298 2170 760...

Page 8: ...steel frame parts Material number Material description Contents pieces 3489830 MAGNETIC TRIGGER 3500 Q S1 VE2 2 3489831 MAGNETIC TRIGGER 3500 Q S1 VE10 10 3489832 MAGNETIC TRIGGER 3500 Q S1 VE100 100...

Page 9: ...ze ranges A B C G B001 2170 760 730 1020 B003 2400 760 980 1020 B039 1700 760 355 952 B041 1700 760 605 952 B166 1855 760 730 952 B253 2170 760 980 952 B296 2170 760 355 1020 B298 2170 760 605 1020 In...

Page 10: ...Installation 10 04 2016 KFV 2 2 Pre drilling the operating lever optional Assembly according to the hardware manufacturer s instructions...

Page 11: ...Installation 11 04 2016 KFV 2 3 Repositioning the latch optional 1 2 3 4...

Page 12: ...re in mm 12 KFV 2 4 Installing the A opener optional A opener Material number Material description Contents pieces 3493787 F1060 A opener 2 0 1 Read the assembly instructions A opener for the installa...

Page 13: ...Installation All dimensions are in mm 13 04 2016 KFV 2 5 Installing the door arrester or daytime release optional 314 5 18 150 D 20 16 34 5 D 2 1 Only when using item B A B...

Page 14: ...ZSK 201 T3 8063 VS35 E 1 3483984 ZSK 201 T3 8063 VS40 E 1 3483985 ZSK 201 T3 8063 VS45 E 1 3483986 ZSK 201 T3 8063 VS50 E 1 3483987 ZSK 201 T3 8063 VS55 E 1 3483988 ZSK 201 T3 8063 VS60 E 1 3483989 Z...

Page 15: ...2 6 Screwing on the multi point lock 9x Installation 15 04 2016 KFV...

Page 16: ...2 7 Cutting the door frame Installation All dimensions are in mm 16 KFV...

Page 17: ...ssembled element with the AS3500 multi point lock including magnetic triggers It is therefore recommended to install the magnetic triggers first when the element is installed on site or prior to trans...

Page 18: ...2 9 Screwing in the frame parts max 5 mm max 5 mm Installation 18 04 2016 KFV...

Page 19: ...2 10 Adjusting the frame parts 1 2 3 Installation 19 04 2016 KFV...

Page 20: ...e lock faceplate Turn the key in the cylinder lock in the opening direction The latch must retract when the key is turned Check the function of the deadbolt Turn the key in the cylinder lock in the lo...

Page 21: ...lever down vertically and hold down 2 Move the slider up on the faceplate vertically 3 Set the handle of the E opener or the KFV daytime latch 115 A B to daytime operation The AS 3500 multi point lock...

Page 22: ...AS 3500 multi point lock from 35 to 80 mm In this way the lever handle and the turn button for the safety lock are arranged on a visual axis The metric fixing screws countersunk 8 mm are provided with...

Page 23: ...ectromechanical opening The deadbolt in the main lock is not locked in this opening procedure The motor is fixed with three screws included If the motor is not installed the screw holes are covered by...

Page 24: ...the cylinder lock To secure the safe function the key must be turned in the opening direction until it reaches the noticeable stop and held in this position until the door opens by a gap of approx 50...

Page 25: ...arranty shall become void if modifications that are not authorised by us or have not been described in this documentation are performed on the product and or individual components or if the product an...

Page 26: ...Appendix 26 04 2016 KFV...

Page 27: ......

Page 28: ...tschland Telefon 49 271 39310 Frankreich Telefon 33 3 89618131 Gro britannien Telefon 44 2476 622000 Italien Telefon 39 02 9353601 sterreich Telefon 43 6225 8301 Polen Telefon 48 77 4477700 Russland T...

Reviews: