Siegenia AEROVITAL Original Operating Instructions Download Page 21

Original operating instructions 

AEROVITAL

06.2018

21

Replace filter

•  The filter should be changed when this is indicated in the display - at least every six months.
•  Only use genuine filters from SIEGENIA. You can purchase replacement filters from SIEGENIA or from specialist retailers.

Caution!

 Activate and remove only the specified device components.

1.  Insert a screwdriver into the left and then the right 

opening of the front panel until the underlying snap 
connection is released at both sides.

2.  Tilt the front panel forwards, lift it off and lay down on the 

side.

3.  Pull the heat exchanger forwards.

Summary of Contents for AEROVITAL

Page 1: ...AERO Wall mounted ventilator with heat recovery AEROVITAL Window systems Door systems Comfort systems ORIGINAL OPERATING INSTRUCTIONS...

Page 2: ......

Page 3: ...tes 5 Scope of delivery 5 Installation 6 Unit description 12 Function 14 Commissioning 15 Operation general 15 Program overview 17 Programming 18 Care and maintenance 20 Accessories 22 Rectification o...

Page 4: ...s The AEROVITAL must be mounted in a vertical position Mounting on inclines e g walls and ceilings is not permissible If the unit is to be used in a room with a heating unit that draws air from the ro...

Page 5: ...n cable for the unit is damaged it must be replaced by SIEGENIA its customer service or an equally qualified person to eliminate hazards Only a qualified electrician may perform any work on the 230 V...

Page 6: ...The base must be level plastered min 350 mm 437 mm 75 mm 78 mm 462 mm Step 2 Marking the holes For in wall mounting and electrical fixed connection 1 For in wall mounting cut out the drilling templat...

Page 7: ...holes 1 Drill the core mounting hole 120 3 Using a hammer drill at an angle of approx 2 to 5 drill a hole through to the outside wall 120 3 2 Drill the four marked mounting holes all drilled holes sh...

Page 8: ...il the pipe is firmly seated 2 Fix the transition point with the adhesive tape included in the delivery The pipe and socket pieces must be firmly interconnected Step 6 Removing the front panel 1 Inser...

Page 9: ...oute the connection cable on the left or right side in the cable duct Note The cable must be neatly routed in the cable duct to prevent it from being pushed through or squeezed during the installation...

Page 10: ...e top opening on the terminal box Step 10 Inserting the blower units 1 Insert the top and bottom blower unit and press lightly against the contacts Note The blower units are kept in this position afte...

Page 11: ...on beside the display and test the functioning of the ventilation unit 5 Switch off the ventilation unit following successful testing Note If the ventilation unit is not working check that the front p...

Page 12: ...06 2018 Unit description AEROVITAL 1 Casing trough 2 Display 3 Infrared receiver 4 Button 5 Casing frame 6 Front panel 7 Air inlet and outlet with cover flaps 8 Cable duct 9 Socket piece 10 Mains cab...

Page 13: ...mperature in degrees Celsius Measuring range from 0 C to 99 C Relative air humidity in Measuring range from 30 to 90 Air throughput level ten possible levels Mode of operation programs P1 P2 P3 Manual...

Page 14: ...d through the two bottom air outlets into the room b a a b b Ventilation elements The heat exchanger partially absorbs the heat from the exhausted indoor air thus heating the supplied fresh air The he...

Page 15: ...property always comply with the following instructions There is a 230 V AC voltage prevailing on the power connection terminals of the unit even when the front panel is removed Do not remove the cover...

Page 16: ...The required air throughput level can be adjusted by pressing the button briefly Unit is switched off Air throughput level 1 Air throughput level 4 Air throughput level 10 Humidity control Remote cont...

Page 17: ...asic ventilation if the room air humidity drops below set value If the room temperature exceeds the set value the air throughput level is increased automatical ly Attention The AEROVITAL only operates...

Page 18: ...in basic ventilation mode and automatically increase the air throughput level from a room air humidity of 58 upwards Step Button press briefly Function Display 1 P2 hold down approx 5 seconds A flash...

Page 19: ...level when an air humidity of 65 or a temperature of 25 C in the room is exceeded Step Button press briefly Function Display 1 P3 hold down approx 5 seconds A flashing value for the room temperature a...

Page 20: ...nit Never use cleaning agents that are aggressive or contain solvents or sharp edged objects as these may damage the surfaces of the casing Never clean the unit with a high pressure cleaner or steam j...

Page 21: ...IA You can purchase replacement filters from SIEGENIA or from specialist retailers Caution Activate and remove only the specified device components 1 Insert a screwdriver into the left and then the ri...

Page 22: ...three layer synthetic composite filter 248843 Spare filter NOx filter F7 L5300200 099010 Rectification of malfunctions In case of a malfunction do not open the device or try to repair it under any cir...

Page 23: ...ng to climatic zone warm average cold 9 5 kWh m a F 30 6 kWh m a B 67 5 kWh m a A d Type WLA ZLA e Type of drive Rotational speed control f Heat recovery system Recuperative g Degree of temperature ch...

Page 24: ...Original operating instructions 06 2018 Dimensions Feedback on documentation We welcome your comments and suggestions on how to improve our documentation Please email your comments to dokumentation s...

Page 25: ...ve documents EN 55014 1 2006 EN 55014 2 1997 A1 EN 61000 3 2 2006 EN 61000 3 3 1995 A1 A2 EN 60335 1 2010 EN 60335 2 80 2003 A1 2004 EN 62233 2008 EN 62233 Br 1 2008 EN 62233 2008 11 EN ISO 12100 2010...

Page 26: ......

Page 27: ......

Page 28: ...85 4861080 China Phone 86 316 5998198 France Phone 33 3 89618131 Germany Phone 49 271 39310 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 Italy Phone 39 02 9353601 Poland Phone 48 77 4...

Reviews: