Original operating instructions
AEROVITAL
06.2018
13
Infrared remote control
1. Infrared transmitter (range approx. 5 m with direct visual
contact to AEROVITAL)
2. Reduce amount of air (P1) reduce humidity/temperature
values and basic ventilation level (P2/P3)
3. Increase amount of air (P1) increase humidity/tempera-
ture values and basic ventilation level (P2/P3)
4. On / Off
Programmable function buttons
5. P1: Pollen protection (manual control)
6. P2: Humidity control
7. P3: Humidity and/or room temperature control
5.
7.
2.
3.
6.
4.
1.
Display
In a normal situation all symbols would not be displayed simultaneously.
Room temperature in degrees Celsius
(Measuring range from 0°C to 99°C)
Relative air humidity in %
(Measuring range from 30% to 90%)
Air throughput level (ten possible levels)
Mode of operation (programs):
P1
P2
P3
Manual ventilation mode (pollen protection)
Automatic ventilation mode (humidity control)
Automatic ventilation mode (humidity and/or room
temperature control)
Operation of the blower units
Filter replacement required
Note!
The filter is monitored on the basis of the current
consumption of the unit. If the unit is operated continuously in
air throughput level 1 or 2, the AEROVITAL processor
switches every 8 hours for approximately two minutes to air
throughput level 5, for measuring technological reasons, to
check the filter. The unit then automatically switches back to
the previously set air throughput level.