Notes on the circuit diagram
a)
If door releases or gate control
systems are fitted and their con-
nected values do not correspond to
12 V AC/DC and min. 20 Ohm, then
either switching output 2 (ATLC ter-
minals 13/14 (output)) or switching
output 3 (ANG terminals 11/12/14
(output)) can be used as a potential-
free door release contact.
To use switching output 2 or 3 as a
potential-free door release contact,
you must configure the corre-
sponding ATLC switching output in
the Access administration interface.
The use of the potential-free
switching outputs is described in
separate diagrams.
(For detailed information, see
page
o)
The COM 611-… code lock
module is always available for
making calls (direct dial via numeric
code).
Together with the EC 602-… easikey
controller, additional control func
-
tions (e.g. access control) can be car
-
ried out for this door station.
q)
Where there are more than 20
backlit call buttons, an additional
12 V AC supply, for instance
TR 603-…, must be installed due
to the current consumption. To use
the additional supply, the jumpers
between the CATLE and the call but
-
tons from b1/c1 to b/c are removed
and the b/c terminals are directly
connected to the additional supply.
The jumpers from the ACM camera
module to CATLE between the ter
-
minals V3/V4 and the terminals b1/
c1 remain as they are.
•
Supply limits ATLC/NG 670-…
(For detailed information, see
page
• The use of an additional power
supply is described in a separate
diagram.
(Examples: For detailed information,
see page
r)
To ensure smooth operation, the
COM 611-… code lock module and
the EC 600-… easikey controller
must be supplied with their own
power supply.
t)
If only control functions (access
control) are run, the Da/Db terminals
of the COM 611-… and EC 600-…
must be connected directly to one
another (without connection to
D1/D2). Only in this case may the
COM 611-…/ EC 600-… of the var-
ious door stations be interconnected
to a group. If no control functions
are needed, then the COM 611-…
code lock module can also be used
without the EC 600-… easikey
controller.
y)
The circuit diagram shows an
exemplary connection of call buttons
with the BRMA.
• (For detailed information, see
page