Notes on the circuit diagram
a)
If door releases or gate control
systems are fitted and their con-
nected values do not correspond to
12 V AC/DC and min. 20 Ohm, then
either switching output 2 (ATLC ter-
minals 13/14 (output)) or switching
output 3 (ANG terminals 11/12/14
(output)) can be used as a potential-
free door release contact.
To use switching output 2 or 3 as a
potential-free door release contact,
you must configure the corre-
sponding ATLC switching output in
the Access administration interface.
•
The use of the potential-free
switching outputs is described in
separate diagrams.
(For detailed information, see
page
b)
Distance between the camera and
AIVS 670-… max. 10 m
d)
A maximum of 12 call but-
tons can be connected at one
BRMA 050-…
The maximum configuration is
16 BRMA 050-… units/192 buttons.
w)
Separate power supply required.