background image

 21

Stabilizer Operation and User guide

   

version 5288-2 - 2018

DECLARATION OF CONFORMITY

Sleipner Motor AS

P.O. Box 519, Arne Svendsensgt. 6-8

N-1612 Fredrikstad, Norway

Declare that the following (Stabilizer) products:

SPS55B

Side-Power Stabilizer System

Actuator kit

SPS66B

Side-Power Stabilizer System

Actuator kit

SPS67B

Side-Power Stabilizer System

Actuator kit

SPS92B

Side-Power Stabilizer System

Actuator kit

SPS93B

Side-Power Stabilizer System

Actuator kit

SPS94B

Side-Power Stabilizer System

Actuator kit

SPS97B

Side-Power Stabilizer System

Actuator kit

VF600

Side-Power Stabilizer System

Vector Fin kit

VF850

Side-Power Stabilizer System

Vector Fin kit

VF1050

Side-Power Stabilizer System

Vector Fin kit

VF1350

Side-Power Stabilizer System

Vector Fin kit

VF1650

Side-Power Stabilizer System

Vector Fin kit

VF1950

Side-Power Stabilizer System

Vector Fin kit

with the following control systems and optional installation accessories:

SCU

Side-Power Stabilizer Control System

Stabilizer Control Unit

FCU

Side-Power Stabilizer Control System

Fin Control Unit

TP-43 Panel

Side-Power Stabilizer Control System

Stabilizer Main operating panel

PHC-3

Side-Power Stabilizer Control System

Hydraulic system control unit

GW-1

Side-Power Control System

Gateway unit

Has been designed and manufactured in accordance to the following technical 

regulations:

DIRECTIVE 2013/53/EU OF THE EUROPEAN PARLIAMENT AND OF THE 

COUNCIL of 20 November 2013 on recreational craft and personal watercraft.

DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIAMENT AND OF THE 

COUNCIL of 26 February 2014 on the harmonization of the laws of the Member States 

relating to electromagnetic compatibility.

DIRECTIVE 2014/35/EU OF THE EUROPEAN PARLIAMENT AND OF THE 

COUNCIL of 26 February 2014 on the harmonization of the laws of the Member States 

relating to the making available on the market of electrical equipment designed for use 

within certain voltage limits.

Fredrikstad, 19

th

of January 2018

Signature

Arne K Skauen

Managing Director, Sleipner Motor AS

Declaration of Conformity

Summary of Contents for TP-43A

Page 1: ...Operation and User guide Stabilizer Systems US Patent US9527556 AU Patent AU2013335369 Patent pending PCT NO2013 050067 Document id 5288 Revision 2...

Page 2: ...and User guide version 5288 2 2018 Contents Information and safety 3 Use Main Menu 5 Alarms and system monitoring 9 Service and Maintenance 15 Technical Specifications 19 Warrany Statement 20 Declara...

Page 3: ...r assemblies penetrating through each side of the yachts hull and hydraulically pow ered with a Side Power compact Hydraulic System The system is electronically gyro controlled utilizing the Side Powe...

Page 4: ...o the fins are left in a fixed position this can make the boat behave differently then expected at high speeds With the stabilizer system active it will ensure that the boats behaviour is predictable...

Page 5: ...reen Touch arrow triangle on the right Green light is indicating GPS available Powerpack VFD enabled Powerpack VFD ready Red light is indicating not ready 1 2 Gain screen Possible to adjust the system...

Page 6: ...3 Stabilizers are active in CRUISING mode Usually in use from 3 4 knots and up Note System change automatically between Cruising At Anchor when both is activated 2 4 Activate Stabilizers to AT ANCHOR...

Page 7: ...ew alarm list 4 2 Alarm list shows current alarms with alarm description To acknowledge alarm s touch ACKNOWLEDGE ALARMS in the bottom of the screen 4 3 Touch the active alarm for more details and Cor...

Page 8: ...IEW HISTORICAL ALARMS 5 1 Go to home page Scroll to System devices Touch System devices 5 2 Touch desired device s 5 3 Historical Alarms pop s up Touch Historical alarms 5 4 Historical Alarms is shown...

Page 9: ...tank beware that the pumps will be destroyed if run dry and can then also cause other damage to the power source driving them If you have to run engines with pumps directly fitted disconnect mechanica...

Page 10: ...ssure Check PHC 3 faults for more information L2 40004 0 210 PHC 3 DEVICE IN MANUAL MODE Trigger when the SCU try to startup PHC 3 and the PHC 3 is running in manual mode Stop running the PHC 3 in man...

Page 11: ...der position is outside the end stop position Run the detect end stop sequence Check encoder belt and pulleys Consult Side Power dealer L2 45001 101 21 FCU Encoder Fin bow starboard Failed Encoder fau...

Page 12: ...ted through the valve when the valve is turned on Check for open circuit L2 45006 102 51 FCU Proportional Valve 1 Fin stern port Current High Current through valve is too high Trigger at 3 75A check f...

Page 13: ...Short Circuit Current through valve is too high Trigger at 1 5A check for short circuit L2 45013 101 13 FCU Float valve Fin bow starboard Open Circuit No current detected through the valve when the v...

Page 14: ...stem wrong configured with thrusters parameter 2001 or 2101 10512 0 51 PHC DOUT LS DUMP Current High LS Dump valve current higher than 4 0A Check wires and connections for short circuit 10513 0 51 PHC...

Page 15: ...the fin and the underside of the hull o Axial play should be checked by measuring the relative distance between the top of the axle shaft and hull plate By using a crow bar on the twin yoke moving an...

Page 16: ...longer periods and either manually rotated every 3 months or started to ensure proper lubrication of the shafts and bearings on its shaft and bearings PREVENTATIVE MAINTENANCE SCHEDULE The maintenanc...

Page 17: ...ic Hoses 1 W 8 Check Shaft Clearances 3 D 9 Replace Lower Shaft Seals 3 D 10 Replace Main Shaft Bearings 3 D 11 Inspect and replace Spherical Bear ings and Cylinder Pins if necessary NOT relevant for...

Page 18: ...Tubes 1 W 7 Inspect Pump Drive Coupling 1 W 8 Inspect Motor and Frame Mounts 1 W 9 Test Hydraulic Oil Quality by means of taking sample 2 W 12 1st 10 Replace Return Filter Element 1 W 24 2nd 11 Repla...

Page 19: ...ons Stabilizer Panel TP 43A Input voltage 8 31VDC Power consumption 3 5W Operating temperature 10 to 70 degrees C Storage temperature 30 to 80 degrees C IP rating front IP67 IP rating rear IP66 Humidi...

Page 20: ...he purchase price Purchaser must submit a statement in writing from a professional boating equipment supplier that the installation instructions of the Installation and Operation Manual have been comp...

Page 21: ...accessories SCU Side Power Stabilizer Control System Stabilizer Control Unit FCU Side Power Stabilizer Control System Fin Control Unit TP 43 Panel Side Power Stabilizer Control System Stabilizer Main...

Page 22: ...22 Stabilizer Operation and User guide version 5288 2 2018...

Page 23: ...23 Stabilizer Operation and User guide version 5288 2 2018...

Page 24: ...t was correct at the time it was published However Sleipner Motor AS can not accept liability for any inaccuracies or omissions it may contain Continuous product improvement may change the product spe...

Reviews: