SECTION 1: PLUMBING INSTALLATION

It is recommended that hot-
water  outlet  pipes  are  fully 
insulated with weather proof 
insulation such as Armaflex. 

The  hot-water  outlet  pipe 

should  be  angled  down  at 
about  15

minimum  for  the 

first  250mm  after  exiting 
from  the  Water  Tank  outlet. 
This  will  create  a  heat  trap 
that  will  avoid  any  thermal 
siphoning  from  the  Water 
Tank.

A drain must be included to allow full and 
complete draining of the Water Tank

A licensed plumber should install the Solarstream. It is the installers responsibility to comply with all AS/NZ Standards, Building 
Codes and Trade Codes of Practice for compliant installations of domestic hot water heaters. In Australia, your plumber should 
also hold a Restricted Split System Air Conditioning Installation and Decommissioning License (Certificate II course under the 
Australian Refrigeration Council’s code RSS03) covering air conditioning and heat pump split systems.

WATER TANK INSTALLATION 

As  the  Solarstream  does  not  require  a  sacrificial  anode,  the  headroom  above  the  cylinder  only  needs  to  accommodate 
convenient installation rather than the one metre or more required to remove/replace the anode. Therefore, the Solarstream 
water tank can be comfortably installed inside or outside of your house in a tight space with little headroom, although the 
Heat Pump unit should be installed outside. 

It  is  best  to  install  the  Water  Tank  close  to  the  outlet  that  has  the  greatest  usage  of  hot-water,  such  as  the  laundry  or 
bathroom. Ensure adequate access for service to the Thermostat and Pressure and Temperature (P&T) relief valve. Ensure 
the specification label is visible. Installation must comply with Australian Standard AS/NZS 3500.4 and any local authority 
regulations.

OUTDOOR

For outdoor (external) installations, a plinth or concrete base pad is recommended in accordance 
with Australian Standard AS/NZS3500.4 to properly support the Solarstream water tank such that the 
water tank is assured of remaining in a vertical position throughout its usable life and not lean over 
due to possible erosion of soil under the plinth, or such risk.

SIESMIC RESTRAINT

Some  building  codes  require  Seismic  Restraint  of  storage  water  heaters  to  be  adequately  supported  against  earthquake 
forces. You should consider restraining the tank to a wall with Stainless Steel bands.

FILLING

Fill the Water Tank by opening all hot-water taps and opening the cold-water inlet to allow air in the system to be expelled. 
Close each hot-water tap; as the flow becomes free of air, check all pipes for any signs of leaks. Power should not be turned 
on until the Water Tank is completely filled with water.

2

Notes:

 327SSAD model has a ring main return 

port just above mid tank. This should be blocked 
off with a 3/4 BSP plug.
Water control valves are not supplied with the 
Solarstream unit.

Ring main return port
Only on model 
SSAD327

 1200mm

(minimun distance)

Pressure Limiting & Stop Valve
with filter or similar valve 
arrangement.  Set at 500kPa

(If needed)
Cold Water
Expansion Valve
700kPa

Pressure & Temperature

Relief  Valve (850kPa)

supplied with 

    Solarstream.  

EXAMPLE OF TYPICAL MAINS PRESSURE HOT WATER SYSTEM INSTALLATION

(Please note, your plumbing may vary from this diagram, 
we recommend discussing your requirements with your
plumber prior to installation)

Summary of Contents for 264SSBD

Page 1: ...lly before undertaking the installation of a Siddons Solarstream Heat Pump Water Heater INSTALLATION AND USER MANUAL INSTALLERS Models Domestic 264SSBD 327SSAD Commercial 327SSAC3 AC4 AC5 AC6 www sidd...

Page 2: ...ection for the Solarstream Heat Pump Water Heater if shelter is available such as an overhanging eave it is a good idea to use it The Heat Pump unit is designed to be installed outside In cold conditi...

Page 3: ...and Pressure and Temperature P T relief valve Ensure the specification label is visible Installation must comply with Australian Standard AS NZS 3500 4 and any local authority regulations OUTDOOR For...

Page 4: ...NCE APART The maximum length of refrigerant line to be connected to the Heat Pump is 9 metres E g 2 metre standard 7 metre extension total 9 metres max Drwg A REFRIGERANT LINES IN DUCTS WALLS OR SURFA...

Page 5: ...ill feel some resistance when the metal diaphragms are punctured to facilitate refrigerant flow keep tightening until you feel the O Ring seal fully seated otherwise gas will leak under the high opera...

Page 6: ...230 240 volt ac power It is a 1 5 mm2 cable protected in UV resistant flexible conduit Fit the wiring loom through the cable hole in top inspection cover on the Water Tank and secure with the conduit...

Page 7: ...ump unit Check the Heat Pump continues to run for at least 20 minutes on first start up Warm water should be evident at hot taps in about 60 minutes Check firstly that the Heat Pump is connected to an...

Page 8: ...ndicated period from the date of the original purchase Should a part of the complete Water Tank component be replaced during this period only the balance of the original warranty will continue to rema...

Reviews: