![Siddons Solarstream 264SSBD Installation And User Manual Download Page 2](http://html1.mh-extra.com/html/siddons-solarstream/264ssbd/264ssbd_installation-and-user-manual_1264795002.webp)
pressure and
temperature
relief valves
Hot Water
take off
circuits
cold water manifold
Outdoor Heat Pump Units
thermostat controls
hot water manifold
Return Water
EQUAL PRESSURE MANIFOLD DESIGN
tempering
valve
tempered
circuits
Refrigerant lines
drain
Hot Water pipes must be fully
insulated to reduce heat loss
CYLINDER SPECIFICATIONS:
327SSAD
264SSBD
Capacity
327 Litres
264 Litres
A
Height
1980 mm
1620 mm
B
Diameter
580 mm
580 mm
C
Hot water outlet
1491 mm
1136 mm
D
Cold water inlet
186 mm
168 mm
Dry weight
73 Kg
62 Kg
Inlet water pressure
500 kPa
500 kPa
Water connections
20mm ~ 3/4 BSP
P&T Valve (supplied)
850kPa
HEAT PUMP SPECIFICATIONS:
A
B
C
D
230~240 V, ac, 50 Hz, 1.38 Kw
Supplied with 3 pin 10 amp Plug
Weight 39 kg
Sound level 53dBA
Operational temp range -5
0
~ 45
0
C
Diameter of airflow outlet 400mm
Refrigerant R417A
Heating capacity @20
0
C =100L / hr
Size L,795mm W,255mm H, 540mm
SPECIFICATIONS:
COMMERCIAL INSTALLATIONS:
Whilst there is no specific need for any external
weather protection for the Solarstream Heat
Pump Water Heater, if shelter is available such
as an overhanging eave, it is a good idea to
use it.
The Heat Pump unit is designed to be installed
outside. In cold conditions it will produce a
lot of condensate water from the evaporator.
This needs to drain away with out causing
any damage to the surrounding building or
material.
The location of the tank and Heat Pump is
flexible. Good design considerations should
be given to:
1. Position the water tank in close proximity
to bathroom and kitchen area to reduce
heat waste.
2. Minimise the distance between Water Tank
and Heat Pump unit for efficiency.
3. Position the Heat Pump unit to maximise
any sun, ambient warm or reflected heat
from wall or building.
1
Solarstream units can be single units or coupled together in many combinations from 3 to 6 units for energy
efficient light commercial installations.
Typical Commercial Examples Are:
Gymnasiums, Fitness Centres, Health Spas
Aged Care Facilities, Medical Centres, Hair Salons
Kindergartens, Day Care Centres, Play Centres
Hostels, Backpackers, Motels Complexes, Caravan Parks
Manufacturing Facilities, Commercial Buildings, Bars, Restaurants
INSTALLATION RECOMMENDATIONS: