LED/fault pattern
Cause
Measures
No object in beam path, no
output signal
Test input (Test) is not con‐
nected properly
Check connection of the test
input. When using female cable
connectors with LED indicators,
make sure the test input is
assigned correspondingly.
8
Disassembly and disposal
The sensor must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electric and electronic devices
•
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
•
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
•
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
9
Maintenance
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
•
Clean the optical interfaces using a plastic cleaner, do not use acetone or methy‐
lated spirits.
•
Check the fittings and plug connectors
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
10
Technical specifications
WTB4FP-xxxxx1
WTB4FP-xxxxx2
Recommended sensing range for the best performance
40 mm … 140 mm
30 mm ... 60 mm
Sensing range max.
4 mm … 220 mm
(Typ)
1)
4 mm ... 100 mm (Typ)
Light spot size / distance
Ø 5 mm (50 mm) (Typ) ,
Ø 4 mm (100 mm) (Typ)
Ø 2 mm (50 mm) (Typ)
Supply voltage U
B
DC 10 ... 30 V
2)
DC 10 ... 30 V
2)
Ripple
≤ 5 Vss
≤ 5 Vss
Output current I
max.
≤ 100 mA
≤ 100 mA
Current consumption
25 mA
25 mA
Communication mode
COM2
COM2
DISASSEMBLY AND DISPOSAL
8
8025665.1DTW /2022-02-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | WTB4FP MultiSwitch
27
Subject to change without notice
en
Summary of Contents for WTB4FP MultiSwitch
Page 58: ...WTB4FP MultiSwitch de en es fr it ja ko pl pt ru zh...
Page 86: ...WTB4FP MultiSwitch de en es fr it ja ko pl pt ru zh...
Page 128: ...WTB4FP MultiSwitch de en es fr it ja ko pl pt ru zh...
Page 142: ...11 11 1 www sick com P N Ident no 11 142 WTB4FP MultiSwitch 8025665 1DTW 2022 02 14 SICK ru...
Page 143: ...WTB4FP MultiSwitch de en es fr it ja ko pl pt ru zh...