The sensor is adjusted and ready for operation.
WTx4Fx-xxxxxxA0Zxx:
6.4
Process data structure
WTB4FP-xxxxxxxxAxx:
A00
A70
A71
A72
A73
A75
IO-Link
V1.1
Process
data
2 bytes
4 bytes
Byte 0: bits 15... 8
Byte 1: bits 7... 0
Byte 0: bits 31...
24
Byte 1: bits 13...
16
Byte 2: bits 15...
8
Byte 3: bits 7... 0
Bit 0 / Data
type
Q
L1
/ Boolean
Bit 1 / Data
type
Q
L2
/ Boolean
Qint.1 /
Boolean
Q
L2
/ Boo‐
lean
Qint.1 / Boolean
Bit... /
Descrip‐
tion / Data
type
2 ...15 /
[empty]
2 ...15 /
[time
measure‐
ment
value] /
UInt 14
2 … 15 /
[counter
value] /
UInt 14
2 … 15 /
[length /
speed
measure‐
ment] /
SInt14
2 /
Qint.1 /
Boolean
2 … 7 / [empty]
Bit... /
Descrip‐
tion / Data
type
3 … 15 /
[time
measure‐
ment
value] /
UInt13
8 … 31 / [carrier
load] / UInt 24
7
Troubleshooting
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 8: Troubleshooting
LED/fault pattern
Cause
Measures
Green LED flashes
IO-Link communication
None
Switching outputs do not
behave in accordance with
1. IO-Link communication
2. Change of the configuration
3. Short-circuit
1. None
2. Adjustment of the configura‐
tion
3. Check electrical connections
Yellow LED lights up, no object
in the path of the beam
The sensing range distance is
too large
Reduce the sensing range
Object is in the path of the
beam, yellow LED does not
light up
Distance between the sensor
and the object is too long or
sensing range is set too short
Increase the sensing range
6
COMMISSIONING
26
O P E R A T I N G I N S T R U C T I O N S | WTB4FP MultiSwitch
8025665.1DTW /2022-02-14 | SICK
Subject to change without notice
en
Summary of Contents for WTB4FP MultiSwitch
Page 58: ...WTB4FP MultiSwitch de en es fr it ja ko pl pt ru zh...
Page 86: ...WTB4FP MultiSwitch de en es fr it ja ko pl pt ru zh...
Page 128: ...WTB4FP MultiSwitch de en es fr it ja ko pl pt ru zh...
Page 142: ...11 11 1 www sick com P N Ident no 11 142 WTB4FP MultiSwitch 8025665 1DTW 2022 02 14 SICK ru...
Page 143: ...WTB4FP MultiSwitch de en es fr it ja ko pl pt ru zh...