SYSTEM DESCRIPTION
3
19
8026508 / V1-0/2021-09|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | VMS4300/5300
•
Coordinates all connected sensors and processes the measured values received.
•
The data is sent to the higher-level customer system via the system controller in a
host telegram with a defined format.
NOTE!
In the case of the VMS5300, the measurement results are saved in the
SIM2000 alibi memory, which is required for legal-for-trade verification.
•
The APU8520 dimensioning controller is the processing unit of the system.
•
The dimensioning controller receives the measuring points from the 2D LiDAR sensors
and uses the 2D sections to calculate a three-dimensional model.
•
Based on this calculated 3D model, the dimensioning controller determines the
dimension values and the so-called box volume.
•
The measurement results are transmitted to the SIM2000 system controller via
CAN bus.
SIM2000
system controller
APU8520
dimensioning
controller