Variant
TiM881P
Vibration resis‐
tance
In accordance with IEC 60068-2-6:2007:
Sine resonance scan 10 Hz to 1,000 Hz; 1 g
Sine test 10 Hz to 150 Hz; 5 g; 20 frequency cycles
In accordance with IEC 60068-2-64:2008
Noise test 10 at 200 Hz, 5 g
rms
, 120 min
Shock resistance
In accordance with IEC 60068-2-27:2008:
15 g, 11 ms; 6 shocks/axis
10 g, 16 ms; 1,000 shocks/axis
Ambient temper‐
ature
Commissioning/switching on: –10 °C ... +50 °C
Operation: –25 °C ... +50 °C
Storage: –40 °C ... +75 °C
Ambient humid‐
ity
Operation: max. 80%
Storage: max. 90%
(relative air humidity, non-condensing)
Ambient light
immunity
80,000 lx
Altitude
< 5,000 m above sea level
Ambient condi‐
tions
In accordance with EN 61010-1:2011-07, Contamination degree 3 outside
housing
Moisture, heat
In accordance with EN 60068-2-30:2005-12
Temperature
change
In accordance with EN 60068-2-14:2009-07
TECHNICAL DATA
10
8024355/15I9/2019-09-30 | SICK
O P E R A T I N G I N S T R U C T I O N S | TiM8xxP
37
Subject to change without notice