12.6
Dimensional drawings
30,7
32,8
L=150
34
1
2
5
3
4
5
30
12
<22
106,8
<22
<14
<14
56,8
4
14
7
56,8
31,6
30,7
29,5
56,8
L
Figure 32: Dimensional drawing of sender and receiver
Table 20: Dimensions based on the protective field height, sender and receiver
Protective field height, nominal in mm
Protective field height, effective = dimension L
in mm
1)
300
313
450
463
600
613
750
763
900
913
1050
1063
1200
1213
1)
The effective protective field corresponds to the entire length of the housing. The test object defined in
the standard IEC
61496-1 is recognized over the entire length of the housing. The limits of the protective
field are identical to ends of the housing.