5
Mounting
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
Note the sensor's maximum permissible tightening torque of 0.65Nm.
NOTE
RAY26P-XXXXX1 (MDO
≥
1 MM), RAY26P-XXXXX3 (MDO
≥
3 MM):
Recommended position of installation: between conveyor belts or conveyor rollers
6
Electrical installation
Operation in standard I/O mode:
The sensors must be connected in a voltage-free state (U
V
= 0 V). The following informa‐
tion must be observed, depending on the connection type:
–
Plug connection: note pin assignment
–
Cable: wire color
Only apply voltage/switch on the voltage supply (U
V
> 0 V) once all electrical connec‐
tions have been established.
Operation in IO-Link mode: Connect the device to a suitable IO-Link master and inte‐
grate in the master or control via IODD/function block. The green LED indicator flashes
on the sensor. IODD and function block are available to download from
under the part number.
Explanation of the connection diagram (following tables):
Alarm = alarm output (see
MF = multifunctional, programmable output
n. c. = not connected
QL1/C = switching output, IO-Link communication
5
MOUNTING
6
8022178.19RH 08.01.2021 | SICK
Subject to change without notice
Summary of Contents for RAY26
Page 1: ...O P E R A T I N G I N S T R U C T I O N S RAY26 MultiTask photoelectric sensors...
Page 19: ...B E T R I E B S A N L E I T U N G RAY26 MultiTask Sensoren de en es fr it ja pt ru zh...
Page 36: ...N O T I C E D I N S T R U C T I O N RAY26 Capteurs multi t ches de en es fr it ja pt ru zh...
Page 53: ...M A N U A L D E I N S T R U E S RAY26 Sensores MultiTask de en es fr it ja pt ru zh...
Page 70: ...I S T R U Z I O N I P E R L U S O RAY26 Sensori MultiTask de en es fr it ja pt ru zh...
Page 87: ...I N S T R U C C I O N E S D E U S O RAY26 Sensores multitask de en es fr it ja pt ru zh...
Page 104: ...RAY26 de en es fr it ja pt ru zh...
Page 111: ...91 1 2 92 1 93 2 79 8022178 19RH 08 01 2021 SICK Subject to change without notice 111...
Page 113: ...1 1 c 1 1 d RAY26 79 8022178 19RH 08 01 2021 SICK Subject to change without notice 113...
Page 118: ...82 WEEE 83 SICK 82 118 8022178 19RH 08 01 2021 SICK Subject to change without notice...
Page 121: ...RAY26 de en es fr it ja pt ru zh...
Page 128: ...106 1 2 107 1 108 2 91 128 8022178 19RH 08 01 2021 SICK Subject to change without notice...
Page 130: ...1 1 c 1 1 d RAY26 3 91 130 8022178 19RH 08 01 2021 SICK Subject to change without notice...
Page 135: ...LED LED 94 WEEE 95 SICK 94 8022178 19RH 08 01 2021 SICK Subject to change without notice 135...
Page 138: ...RAY26 de en es fr it ja pt ru zh...
Page 145: ...121 1 2 122 1 123 2 103 8022178 19RH 08 01 2021 SICK Subject to change without notice 145...
Page 147: ...1 1 c 1 1 d RAY26 103 8022178 19RH 08 01 2021 SICK Subject to change without notice 147...
Page 152: ...C 106 WEEE 107 SICK 106 152 8022178 19RH 08 01 2021 SICK Subject to change without notice...