8
Error messages
If an error message is displayed, press the Esc pushbutton to return to the main menu.
Message
Description
No configurations saved!
No configuration files are saved in the selected
memory location.
No saving:
Memory full
Please delete files!
The internal memory is full.
Delete files or save configuration to the SD
card.
Error!
No firmware file!
The selected file is not a firmware file. Select a
valid file for the update.
Error!
Invalid checksum!
The selected firmware file is corrupt.
Error!
Size Incorrect!
The file size for the selected firmware file is not
permitted.
Communication error!
Errors occurred during communication
between the PGT-12-Pro and the device. Pro‐
gramming was not executed. Repeat the proc‐
ess.
SD card empty!
No files available on the SD card.
SD failure
No SD card
No SD card inserted.
SD failure
Write-protected
Write protection is activated on the SD card.
Disable write protection to use the card with
the PGT-12-Pro.
No saving:
File name full
Please change folder!
File numbering for this device type has
reached the maximum for this folder. Select
another storage location.
File system error!
Failed to access file system. Repeat the proc‐
ess.
SD failure
No FAT file system
The SD card is not formatted in the FAT32 file
system. Format the SD card to FAT32 first. The
SD card can then be used.
SD failure
Not ready
The SD card is not ready for use. Repeat the
process.
No configuration file!
The selected file is not a valid configuration
file.
SD card failure!
Error when accessing the SD card.
Battery low
Please replace!
Insufficient battery voltage. Insert new batter‐
ies.
Error!
Invalid mapping
Mapping has not been changed
Plausibility error when creating TPDO mapping.
Set up to 5 positions with a total bit length of
64 bits; there must be no gaps between the
positions.
OPERATING INSTRUCTIONS
8019724/1EJJ/2022-01-05 | SICK
O P E R A T I N G I N S T R U C T I O N S | PGT-12-Pro
35
Subject to change without notice