Operating Instructions
PBS Hygienic
O p e r a t i n g I n s t r u c t i o n s | S I C K
3 5
8016359/2013-05-20 | PBS Hygienic
Subject to chance without notice
3.1 Features
Pressure units
bar, MPa, psi and kg/cm
2
Measuring ranges
Gauge pressure
0 bar ... 1 bar up to 0 bar ... 25 bar
Absolute pressure
0 bar ... 1 bar up to 0 bar ... 25 bar
Compound pressure
–1 bar ... 0 bar up to –1 bar ... +24 bar
Overload protection
2-fold
Process temperature
–20 °C ... +100 °C, +135 °C for max. 1 h
–20 °C ... +125 °C, +150 °C for max. 1 h
1)
Signal output and maximum ohmic load R
A
4 mA ... 20 mA (R
A
≤ 0,5 kOhm)
0 V ... 10 V (R
A
> 10 kOhm)
Zero point adjustment
Max. + 3 % of span
Switching output
Transistor switching output PNP or NPN Number: 1 or 2
(With IO-Link: C/Q1: PNP)
Function: normally open/normally closed, windows- and hysteresis functi-
on freely adjustable
Contact rating: Supply voltage L
+
– 1 V [V DC]
Max. switching current: 250 mA, with IO-Link: C/Q
1
: 100 mA, Q
2
: 250 mA
Switching delay: 0 s ... 50 s (adjustable)
Response time: ≤ 10 ms
Individually adjustable via external control buttons
Setting accuracy: ≤ 0,5 % of span
Rotatable housing
Display against housing with electrical connection: 330 °
Housing against process connection: 320 °
Display
14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable
by 180°
Accuracy: ≤ 1 % of span ± 1 digit
Update: 1,000, 500, 200, 100 ms (adjustable)
1)
Only for process connection G 1 hygienic.
3. Technical data
3. Technical data