Real distance
Measured value without averaging (Avg: OFF)
Output signal
Time t
1
Measured value with median (Avg: 63)
2
4
Measured value with averaging (Avg: 64)
3
4
3
2
1
>
Measurement
>
>
Default settings
>
>
Measured value filter
>
Parameter
Factory setting
Do not use a filter
x
Averaging filter:
4, 8, 16, 32, 64, 512
-
Median filter:
3, 7, 15, 31, 63, 511
-
8.3.2.3
Bit filter
The bit filter for switching outputs determines how often an identical output state has to
recur consecutively before the signal at the switching output changes accordingly.
If the defined number is not reached, the switching output remains unchanged. This
may increase the reliability in the application if the distance value fluctuates around the
selected switching point. This will not affect the cycle time or the output rate.
>
Measurement
>
>
Default settings
>
>
Bit filter
>
8
OPERATION VIA DISPLAY
34
O P E R A T I N G I N S T R U C T I O N S | OD1000
8019642/ZJW1/2017-04-03 | SICK
Subject to change without notice