4.3
Location of the O-ring and support ring
1
2
Figure 12: O-ring and support ring
1
Support ring
2
O-ring
The O-ring and support ring are pre-installed as shown in the figure and prevent oil from
penetrating into the connector area.
4.4
Installing the sensor in the cylinder
4.4.1
Installing using an M12 connector system
The M12 connector system has an enclosure rating of IP69K and is pre-assembled
ready for installation.
NOTE
When selecting the mating connector, ensure that it also has an enclosure rating of
IP69K.
Figure 13: Installation steps
1.
Lubricate the O-ring and support ring.
2.
Guide the connector system and its connecting cables carefully through the cylin‐
der wall.
Figure 14: Tensile load at edges
NOTICE
Risk of damage to the connecting cables during installation.
Tensile loads and sharp edges can damage the stranded wires and connecting
cables of the connector system.
b
Avoid tensile loads and look out for sharp edges when installing the connec‐
tor system.
4
MOUNTING