Electrical data
Current signal
100 ≤ RL ≤ 500 (load resistance)
Switch-on current:
12 VDC supply voltage
2.5 A / 50 µsec typical
24 VDC supply voltage
5.0 A / 50 μsec typical
Over voltage protection
ISO 16750-2: ≤ + 36 VDC on all poles
Reverse polarity protection
ISO 16750-2: on all poles
Insulation resistance
ISO 16750-2: Riso ≥ 10 MΩ, 60 sec
Dielectric strength
ISO 16750-2: 500 VDC (0 VDC to housing)
Dimensions
Size
48F7 mm (for installation in a 48H8 clearance)
Unusable range:
Null zone (zero point)
30.0 mm
Damping (end point)
30.0 mm/ 36.0 mm/ 63.0 mm (depending on type)
Pressure pipe
Ø 7 mm or 10 mm (depending on type)
O-ring
Ø 40.87 mm x 3.53 mm
Support ring
Ø 42.6 mm x 48 x 1.4 mm
M12 flange
EN 61076-2-101 DM 20 x 20 mm - 14 mm hole pattern
3-wire cable
Ø 3.2 mm, 3 x 0.32 mm² (AWG22),
stripped 300 … 10,000 mm (depending on type)
Material
Pressure pipe
Stainless steel 1.4306, AISI 304L
Electronics housing
Stainless steel 1.4305, AISI 303
O-ring
NBR 70
Support ring
PTFE
M12 male connector insert
Glass fiber reinforced polyamide, nickel-/gold-plated brass contacts
M12 flange
Stainless steel with O-ring (NBR70)
Ambient data
EMC
EU Directive 2014/30/EU CE marking
EU Directive 2009/64/EU Agricultural machinery
Generic standards
Immunity as per EN 61000-6-2
EN 61000-4-3 High-frequency electromagnetic fields
EN 61000-4-4 Conducted fast transients (burst)
EN 61000-4-5 Conducted emission voltage (surge) Class2
EN 61000-4-6 Conducted high-frequency signals
EN 61000-4-8 Magnet fields
Radiated emissions as per EN 61000-6-3
CISPR25 High-frequency radiated interference
Immunity
Agricultural and forestry machines (ISO 14982)
Construction machines (EN 13309/ ISO13766)
ISO 11452-2 High-frequency electromagnetic fields
ISO 11452-4 Bulk Current Injection
ISO 11452-5 Strip Line Method
Radiated emission
Agricultural and forestry machines (ISO 14982)
Construction machines (EN 13309/ ISO13766)
CISPR25 High-frequency radiated interference
Transient pulses
ISO 7637-2 Test pulse 1/ 2a/2b /3a/3b /4 /5a/5b
ESD (air and contact discharge)
EN 61000-4-2
ISO/TR 10605
TECHNICAL DATA
10
8021473/2017-08-08 | SICK
T E C H N I C A L I N F O R M A T I O N | MAX48
31
Subject to change without notice