Operating Instructions
Chapter
9
M4000 Adv., Adv. A/P, Area
8010797/YT72/2016-02-19
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
97
Subject to change without notice
Commissioning
Remove the alignment template from the individual mirror.
Adhere the alignment template for the sender to the beam on the sender that is closest
to the 7
E
segment display.
The alignment template for the sender is correctly positioned on the sender
(see Fig. 65), when …
– the circular opening is exactly over the beam optics
and
– the tabs on the template are exactly positioned on the edges of the sender housing
and point upward from the 7
E
segment/LED display.
Align the deflector mirror (depending on the mirror columns, you may need to remove
the cover plate first). With the aid of three adjusting screws, you can finely adjust the
individual mirror (see Fig. 66). The optimal alignment is achieved when the alignment
beam is incident in the middle of the rectangular hole in the alignment template.
Fig. 64: Alignment of the
receiver to the deflector
mirror using the laser
alignment aid
Note
Fig. 65: Attach the alignment
template to the sender
The laser beam is incident in the
middle of the hole in the alignment
template.
Deflector mirror
Laser deflector mirror
Adhere alignment template to
edges of the housing
Top edge of the
7
4
segment/LED display