Chapter
1
Operating Instructions
M4000 Adv., Adv. A/P, Area
8
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
8010797/YT72/2016-02-19
Subject to change without notice
About this document
1.4
Scope
These operating instructions are original operating instructions.
These operating instructions apply to the M4000 Advanced, M4000 Advanced A/P and
M4000 Area 60/80 multiple light beam safety devices with one of the following entries on
the type label in the field
Operating Instructions
:
8010794_WP70
8010794_YT72
This document is part of SICK part number 8010794 (operating instructions
“M4000 Advanced, M4000 Advanced A/P and M4000 Area 60/80 — Multiple light beam
safety device” in all available languages).
For the configuration and diagnostics of these devices you require CDS (Configuration &
Diagnostic Software) version 3.6.4 or higher. To determine the version of your software
version, select the
Module-Info...
option in the
?
menu.
The general requirements for muting are defined in CLC/TS 62 046.
1.5
Abbreviations and terms
Application diagnostic output = configurable signal output that indicates a specific status
of the protective device
Distance between two neighbouring beams, measured from the middle of one beam to the
middle of the other.
SICK Configuration & Diagnostic Software = software for the configuration and diagnostics
of your M4000 multiple light beam safety device
External device monitoring
Enhanced function interface = safe SICK device communication
Electro-sensitive protective equipment (e.g. M4000)
A temporary automatic suppression of one or more safety function/s by safety-related
parts of the control system.
Output signal switching device
Output weak signal = contamination signal
Programmable logic controller
Minimum size of a test rod that is reliably detected by the protective device The resolution
is measured from the outside edge of a beam to the opposite outside edge of the
neighbouring beam.
Safety Data Link = SICK safety interface (connection for OSSD and EFI of an ESPE)
The SICK products in the sens:Control series include safety relays, safety controllers and
network solutions. If reference is made in this document to sens:Control devices, safety
controllers and network solutions are meant.
The UE403 safety relay is an accessory for the SICK M4000 Advanced multiple light beam
safety device. It extends the technical application possibilities of the M4000 Advanced.
Note
Note
ADO
Beam separation
CDS
EDM
EFI
ESPE
Muting
OSSD
OWS
PLC
Resolution
SDL
sens:Control
UE403