Chapter
6
Operating Instructions
Laser measurement sensor LD-MRS
84
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8012948/ZMQ0/2017-06-09
Commissioning and configuration
Recommendation
In addition, the parameter set can be saved as a project file (spr
file with configuration data)
and archived on the computer.
Fig. 6-1:
Principle of data storage
6.4.1
Configure the LD-MRS
You can configure the LD-MRS interactively using SOPAS-ET.
All of the configurable parameters for the LD-MRS are compiled in a device description (jar
or sdd
file) for SOPAS-ET. You can access the parameters through the project tree for the
device description.
The functions of the parameters are explained depending on the context in an online help
(press
[F1]
). The valid value range and default are listed n the display window P
ARAMETER
INFO
(right-click when the pointer is over the parameter.
Important
The program access to the LD-MRS is password protected. After configuration is successful,
change the password to ensure protection.
Use the structure of the project tree in SOPAS-ET to configure the required parameters for
your application.
Do not turn off the power during configuration.
If the power is turned off during configuration, all of the configured parameters are lost.
1. In the O
PTIONS
menu, select the command L
OG
ON
TO
THE
DEVICE
, and log on with the pass-
word "client" as an A
UTHORIZED
C
LIENT
.
2. Configure the LD-MRS using the parameters in the SOPAS-ET for the desired applica-
tion.
You can find help on using the program interface and individual options in SOPAS-ET:
Reset configuration
Recommendation
To reset the LD-MRS back to its original settings, first export the data of a device with the
original settings to a file. This device data can later be loaded to a configured device to reset
the configuration to the original settings.
Parameter set in the
main memory of the
LD-MRS
Permanently saved
parameter set
Factory defaults of the
LD-MRS
RAM
EEPROM
ROM
Opened project file with
current parameter set
RAM
Saved project file with
archived parameter set
(*.spr)
Hard disk
Upload
Download
LD-MRS
Computer with SOPAS-ET
User level
Password
Authorized client
Client
Tab. 6-2: Password