5.2
Note on the swivel connector
NOTICE
Damage to the connector unit from over-tightening!
The connector unit on the device has two opposite end positions.
■
Do not rotate the connector unit from either of the two end positions by more than
270°.
5.3
Wiring the interfaces
5.4
Pin assignment of the connections
Overview of pin assignment
Table 2: M12 male connector, 5-pin
2-P
1-P
dyn.
AUTO
1
L+
L+
L+
L+
2
Q
A
U
Q
A
U
Q
A
U
Q
A
U
3
M
M
M
M
4
Q
Q
Q
Q
5
IN
A
U
IN
A
U
IN
A
U
IN
A
U
Legend
L+ = supply voltage
Q
A
U = voltage output
M = ground
Q = switching output
IN
A
U = analog input voltage
5.5
Connecting the supply voltage
NOTICE
Risk of damage to the device!
The device can become damaged if it is connected to a voltage supply that is already
switched on.
•
Only connect the device when the supply cable is de-energized.
The device must be connected to a power supply unit with the following properties:
•
Supply voltage DC 10,8 V – 28,8 V (SELV/PELV as per currently valid standards)
•
Electricity source with at least 4 W power
To ensure protection against short-circuits/overload in the customer’s supply cables,
the wire cross-sections used must be appropriately selected and protected.
5
ELECTRICAL INSTALLATION
18
O P E R A T I N G I N S T R U C T I O N S | KTS/KTX Prime
8020706.1E9P/2022-04-26 | SICK
Subject to change without notice