Operating the device
38
© SICK AG • Subject to change without notice • 8016441/2013-11-22
"Count" menu
The "Count" menu displays all counts for the switching events in Table 10
(page 38). You can reset the counter by switching the device off and on
again.
The "Count" menu is accessed via the following menu path:
Operating mode
→
→
Menu
→
→
Count
Press the
pushbutton to display the "OptBrk" parameter.
Parameter
Description
OptBrk
Number of light path interruptions
WrnTmp
Number of temperature warnings
EthLink
Number of Ethernet link interruptions
Reset
Yes: Resets all counters in the "Count" menu.
Table 10: "Count" menu
NOTE
If a value or a piece of information in menu mode
consists of more than six characters, the characters are
automatically shown successively in the display.
"SwVers" menu
The "SwVers" menu displays all information relating to the software.
The "SwVers" menu is accessed via the following menu path:
Operating mode
→
→
Menu
→
→
SwVers
Press the
pushbutton to display the "SwVers" parameter.
Parameter
Description
SwVers
Displays the version number
Table 11: "SwVers" menu
NOTE
If a value or a piece of information in menu mode
consists of more than six characters, the characters are
automatically shown successively in the display.
"HwVers" menu
The "HwVers" menu displays all information relating to the hardware.
The "HwVers" menu is accessed via the following menu path:
Operating mode
→
→
Menu
→
→
HwVers
Press the
pushbutton to display the "HwVers" parameter.
Parameter
Description
HwVers
Displays the version number
Table 12: "HwVers" menu