8016441/2013-11-22 • © SICK AG • Subject to change without notice
23
Mounting
Mounting the ISD400 Pro and other
optical devices
a
a > d x 0.0083
d
Fig. 6: Arranging the ISD400 Pro and a DL100 Hi distance-measuring device
1
DL100 Hi distance-measuring device
2
Reflector
3
ISD400-7xx1, red
4
ISD400-7xx2, infrared
a Minimum distance
Formula
a > d x 0.0083
Example
• Measuring range: 0.2 … 150 m
• d (measuring distance): 100 m
Calculation
a > 100 m x 0.0083
Minimum distance result
a > 0.83 m