5
Mounting
5.1
Safety
DANGER
Hazard due to unexpected starting of the machine
Death or severe injury
b
Make sure that the dangerous state of the machine is and remains switched off.
DANGER
Bypassing the protective device
Hazard due to lack of effectiveness of the protective device
b
Eliminate any temptation to tamper with the safety locking device by taking at least
one of the following measures:
°
Attach safety switches with a cover or with shielding, or ensure they are out of
reach.
°
If possible, use permanent mounting methods for actuators (e.g., welding,
glue, disposable screws, or rivets).
CAUTION
Hot housing
Risk of burns
b
At ambient temperatures > 40 °C, protect the safety locking device from uninten‐
tional touching by people.
NOTICE
If incorrectly installed or the ambient conditions are not suitable, the safety locking
device can get damaged.
b
Arrange the safety switch and actuator so that damage due to unintentional out‐
side influences is prevented.
b
Do not use safety switch and actuator.
b
The set-up and mounting of the safety switch and actuator must be stable enough
to maintain proper operation.
b
Use only reliable mounting elements that can only be removed with tools.
b
If an opening is created in the physical guard due to alignment errors, it must not
impair the protective function.
b
At ambient temperatures > 40 °C, protect the safety switch from contact with
flammable materials.
5.2
Converting the actuating head
1.
Insert the actuator into the actuating head.
2.
Loosen the screws on the actuating head.
3.
Turn the actuating head in the desired direction.
5
MOUNTING
14
O P E R A T I N G I N S T R U C T I O N S | i15 Lock
8020548/ZT59ZT59/2019-01-17 | SICK
Subject to change without notice