4.
Tighten the screws to 0.6 Nm.
5.
Seal unused actuation slots with the supplied slot covers.
5.3
Mounting
1.
Insert the actuator into the actuating head.
2.
Connect the safety switch to the fixed part of the protective device with positive
locking with 2 M5 screws. Tightening torque: 1.4 Nm.
3.
In addition, insert 2 M5 coiled spring pins to fasten the safety switch.
4.
Connect the actuator permanently to the moving part of the protective device so it
cannot be disengaged.
5.
Fit an additional stop for the moving part of the protective device.
5.4
Protection from environmental influences
The prerequisite for a proper and permanent safety function is protection of the actuat‐
ing head from foreign bodies such as chips, sand, beams of light, etc.
When doing painting work, cover the actuation slot, the actuator and the type label.
MOUNTING