Commissioning
1 Check the application conditions: Adjust the sensing range and distance to the
object or background and the remission capability of the object according to the
corresponding diagram [H] (x = sensing range, y = transition range between the set
sensing range and suppression of the background as a % of the sensing range
(object remission / background remission). Remission: 6% = black
, 18% = grey
, 90% = white
(referring to standard white as per DIN 5033).
The minimum distance (= y) for background suppression can be determined from
diagram [H] as follows:
Example: x = 40 mm, y = 10% => 10% % of 40 mm = 4 mm. That is, the back‐
ground is suppressed at a distance of > 44mm from the sensor.
6%/90%
18%/90%
90%/90%
25
20
15
10
5
0
mm
(inch)
50
(1.57)
100
(3.94)
150
(5.91)
200
(7.87)
250
(9.84)
300
(11.81)
Distance in mm (inch)
1
2
3
Image: H
2 Mount the sensor using a suitable mounting bracket (see the SICK range of acces‐
sories).
The maximum permissible tightening torque is listed in Table K.
Note the preferred direction of the object relative to the sensor.
3 The sensors must be connected in a voltage-free state (V
S
= 0 V). The information
in the graphics [B] must be observed, depending on the type of connection:
–
Male connector connection: pin assignment
–
Cable: core color
2
CORRECT USE
2
8019057.16B5 | SICK
Subject to change without notice
Summary of Contents for GRTB18
Page 52: ...Image G 68 I 69 LED LED LED LED LED F 67 50 8019057 16B5 SICK Subject to change without notice...
Page 54: ...GRTB18 S 4 1 1 5 6 A UV B D 72 52 8019057 16B5 SICK Subject to change without notice...
Page 59: ...Image G 77 I 78 C F 76 8019057 16B5 SICK Subject to change without notice 57...